GE PIB 102A MV7306P23阿爾斯通控制板的應(yīng)用

作者:xqt 發(fā)布時(shí)間:2022-09-19 08:53:30 次瀏覽

GE PIB 102A MV7306P23阿爾斯通控制板的應(yīng)用熱備CPU冗余功能有關(guān)熱備用CPU冗余系統(tǒng)的配置和操作的詳細(xì)信息,請(qǐng)參閱PACSystems熱備用CPU冗余用戶手冊(cè),GFK-2308。? 通過(guò)以太網(wǎng)網(wǎng)絡(luò)接口單元(ENIU)支持單個(gè)和冗余以太網(wǎng)遠(yuǎn)程I/O局域網(wǎng)模塊? 支持單工和冗余控制的PROFINET遠(yuǎn)程IO(需要固件版本8.00或更高版本)? 在任何一個(gè)單點(diǎn)故障中幸存? 無(wú)碰撞開(kāi)

GE PIB 102A  MV7306P23阿爾斯通控制板的應(yīng)用

熱備CPU冗余功能

有關(guān)熱備用CPU冗余系統(tǒng)的配置和操作的詳細(xì)信息,請(qǐng)參閱PACSystems熱備用CPU冗余用戶手冊(cè),GFK-2308。

? 通過(guò)以太網(wǎng)網(wǎng)絡(luò)接口單元(ENIU)支持單個(gè)和冗余以太網(wǎng)遠(yuǎn)程I/O局域網(wǎng)模塊

? 支持單工和冗余控制的PROFINET遠(yuǎn)程IO(需要固件版本8.00或更高版本)

? 在任何一個(gè)單點(diǎn)故障中幸存

? 無(wú)碰撞開(kāi)關(guān)

o同步CPU

o單掃描切換

PIB 102A  MV7306P23

o傳輸數(shù)據(jù)大小可達(dá)2M字節(jié);在CPU硬件配置和變量屬性中選擇

? 支持兩條冗余通信鏈路 故障部件的在線修復(fù)

? 在線編程

? 冗余存儲(chǔ)器交換模塊

o用于角色切換的手動(dòng)撥動(dòng)開(kāi)關(guān),用于將控制從活動(dòng)單元轉(zhuǎn)換到備用單元

o冗余狀態(tài)指示燈

? 應(yīng)用程序啟動(dòng)的角色切換,將活動(dòng)單元切換到備份狀態(tài)

? 冗余狀態(tài)位和消息記錄

? 內(nèi)存錯(cuò)誤檢查和糾正(ECC)、單位糾正和多位檢查

? 背景診斷

HSB控制策略

HSB控制策略具有以下特點(diǎn):

? 在重新同步時(shí),活動(dòng)單元不會(huì)自動(dòng)切換到主單元

? 輸出數(shù)據(jù)傳輸中必須包括關(guān)鍵控制數(shù)據(jù)和所有冗余輸出

? 從活動(dòng)單元到備用單元的無(wú)碰撞切換本產(chǎn)品用于RX3i系統(tǒng)。其部件被視為開(kāi)放式設(shè)備(帶電用戶可接近的電氣部件),并且必須安裝在最終外殼中,即:制造以提供安全。外殼至少應(yīng)提供一定程度的固體防護(hù)小到12mm的物體(例如手指)。這相當(dāng)于NEMA/UL 1型外殼或IEC60529 IP20提供至少2級(jí)污染環(huán)境的等級(jí)。有關(guān)安裝RX3i機(jī)架系統(tǒng)的詳細(xì)信息,請(qǐng)參閱PACSystems RX3i系統(tǒng)手冊(cè),GFK-2314。

危險(xiǎn)區(qū)域的安裝以下信息適用于帶有危險(xiǎn)區(qū)域UL標(biāo)志或ATEX標(biāo)志的產(chǎn)品:

爆炸性環(huán)境:1類2組ABCD

? 該設(shè)備為開(kāi)放式設(shè)備,安裝在適用于只有使用工具才能訪問(wèn)的環(huán)境。

? 適用于I類2類A、B、C和D組危險(xiǎn)場(chǎng)所或非危險(xiǎn)場(chǎng)所

? 警告-爆炸危險(xiǎn)-替換部件可能會(huì)損害I類的適用性,第2部分。

? 警告-當(dāng)處于危險(xiǎn)位置時(shí),在更換或接線前關(guān)閉電源模塊。

? 警告-爆炸危險(xiǎn)-只能在已知無(wú)危險(xiǎn)的區(qū)域更換電池。

ATEX 2區(qū)該模塊必須安裝在符合EN60079-15認(rèn)證的外殼中,用于IIC組2區(qū)防護(hù)等級(jí)為IP54。外殼只能使用工具打開(kāi)。

Hot Standby CPU Redundancy Features

For details on the configuration and operation of a Hot Standby CPU redundancy system, refer to the PACSystems

Hot Standby CPU Redundancy User’s Manual, GFK-2308.

? Supports single and redundant Ethernet remote I/O LANs through Ethernet Network Interface Unit (ENIU)

modules

? Supports simplex and redundantly controlled PROFINET remote IO (requires firmware version 8.00 or later)

? Survives any one single point of failure

? Bumpless switching

o Synchronized CPUs

o One scan switching

o Transfer data size up to 2Mbytes; selected in CPU hardware configuration and in variable properties

? Supports two redundancy communications links

? Online repair of failed component

? Online programming

? Redundancy Memory Xchange Module

o Manual toggle switch for role switching, which transitions control from the active unit to the backup unit

o Redundancy status LEDs

? Application-initiated role switching to switch the active unit to backup status

? Redundancy status bits and message logging

? Memory error checking and correction (ECC) single bit correcting and multiple bit checking

? Background diagnostics

HSB Control Strategy

The HSB control strategy has the following characteristics:

? Active unit does not automatically switch to primary on resynchronization

? Critical control data plus all redundant outputs must be included in the output data transfer

? Bumpless switchover from active unit to backup unit This product is intended for use with the RX3i system. Its components are considered open equipment (having live

electrical parts that may be accessible to users) and must be installed in an ultimate enclosure that is

manufactured to provide safety. At a minimum, the enclosure shall provide a degree of protection against solid

objects as small as 12mm (fingers, for example). This equates to a NEMA/UL Type 1 enclosure or an IEC60529 IP20

rating providing at least a pollution degree 2 environment. For details about installing RX3i rack systems, refer to

PACSystems RX3i System Manual, GFK-2314.

Installation in Hazardous Areas

The following information is for products bearing the UL marking for Hazardous Areas or ATEX marking for

explosive atmospheres:

CLASS 1 DIVISION 2 GROUPS ABCD

? This equipment is an open-type device and is meant to be installed in an enclosure suitable for the

environment that is only accessible with the use of a tool.

? Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or nonhazardous locations

only.

? Warning – EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,

DIVISION 2.

? Warning – WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING

MODULES.

? Warning – EXPLOSION HAZARD - BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NONHAZARDOUS.

ATEX Zone 2

This module must be mounted in an enclosure certified in accordance with EN60079-15 for use in Zone 2, Group IIC

and rated IP54. The enclosure shall only be able to be opened with the use of a tool.