IGCT可控硅5SHX1960L0004模塊化發(fā)展
SIE中的控制器標(biāo)簽。DATA保存要在處理器和MVI56E-SIE模塊。此讀寫數(shù)據(jù)在處理器之間傳輸和模塊為“頁(yè)面”或塊,數(shù)據(jù)長(zhǎng)度不超過(guò)200個(gè)字。SIE.data的數(shù)據(jù)類型。ReadData和SIE.DATA。WriteData控制器標(biāo)記數(shù)組是包含可變?cè)財(cái)?shù)的整數(shù)數(shù)組。SIE.DATA.讀取數(shù)據(jù)ReadData是一個(gè)控制器標(biāo)記數(shù)組,可自動(dòng)調(diào)整以匹配輸入的值在配置的讀取寄存器計(jì)數(shù)(第35頁(yè))參數(shù)中。為了便于使用,這個(gè)數(shù)組應(yīng)該是200個(gè)單詞的倍數(shù)。此數(shù)據(jù)翻至從模塊到處理器,每次200字。梯形圖邏輯放置數(shù)據(jù)
接收到ReadData數(shù)組中的正確位置。此數(shù)據(jù)用于狀態(tài)和處理器梯形圖邏輯中的控制。
ReadData數(shù)組與模塊的ReadData區(qū)域的內(nèi)容相關(guān)內(nèi)部數(shù)據(jù)庫(kù)。要查看模塊內(nèi)部數(shù)據(jù)庫(kù)中的實(shí)際寄存器,請(qǐng)?jiān)L問(wèn)從ProSoft Configuration Builder的診斷菜單中顯示數(shù)據(jù)庫(kù)。更多信息,請(qǐng)參閱PCB Diagnostics WriteData部分,它是一個(gè)控制器標(biāo)記數(shù)組,可自動(dòng)調(diào)整以匹配輸入的值在配置的寫入寄存器計(jì)數(shù)(第36頁(yè))參數(shù)中。為了便于使用,這個(gè)數(shù)組應(yīng)該是200個(gè)單詞的倍數(shù)。此數(shù)據(jù)上翻至從處理器到模塊,每次200字。梯形圖邏輯將寫入數(shù)據(jù)傳輸?shù)捷敵鰣D像以傳輸?shù)侥K。此數(shù)據(jù)從處理器向模塊發(fā)送狀態(tài)和控制信息,以便在上的其他節(jié)點(diǎn)中使用網(wǎng)絡(luò)WriteData數(shù)組與模塊的“寫入數(shù)據(jù)”區(qū)域的內(nèi)容相關(guān)內(nèi)部數(shù)據(jù)庫(kù)。
要查看模塊內(nèi)部數(shù)據(jù)庫(kù)中的實(shí)際寄存器,請(qǐng)?jiān)L問(wèn)從ProSoft Configuration Builder的診斷菜單中顯示數(shù)據(jù)庫(kù)。更多信息,請(qǐng)參閱PCB診斷診斷和故障排除部分
該模塊提供以下診斷和故障排除信息
形式:
? 模塊前面的LED狀態(tài)指示燈提供有關(guān)模塊的信息地位
? 模塊中包含的狀態(tài)數(shù)據(jù)可以在ProSoft Configuration Builder中查看通過(guò)以太網(wǎng)端口。
? 狀態(tài)數(shù)據(jù)值從模塊傳輸?shù)教幚砥鳌?br/>
The controller tags in SIE.DATA hold data to be transferred between the processor and
the MVI56E-SIE module. This read and write data is transferred between the processor
and module as "pages," or blocks, of data up to 200 words long.
The data types for the SIE.DATA.ReadData and SIE.DATA.WriteData controller tag
arrays are integer arrays containing variable numbers of elements.
SIE.DATA.ReadData
ReadData is a controller tag array that automatically adjusts to match the value entered
in the Read Register Count (page 35) parameter of the configuration. For ease of use,
this array should be dimensioned as a multiple of 200 words. This data is paged up to
200 words at a time from the module to the processor. The ladder logic places the data
received into the proper position in the ReadData array. This data is used for status and
control in the processor ladder logic.
The ReadData array is related to the contents of the Read Data area of the module's
internal database. To view the actual registers in the module's internal database, access
the database display from ProSoft Configuration Builder's Diagnostics menu. For more
information, see the section on PCB Diagnostics WriteData is a controller tag array that automatically adjusts to match the value entered
in the Write Register Count (page 36) parameter of the configuration. For ease of use,
this array should be dimensioned as a multiple of 200 words. This data is paged up to
200 words at a time from the processor to the module. The ladder logic places the write
data into the output image for transfer to the module. This data is passed from the
processor to the module for status and control information for use in other nodes on the
network.The WriteData array is related to the contents of the Write Data area of the module's
internal database. To view the actual registers in the module's internal database, access
the database display from ProSoft Configuration Builder's Diagnostics menu. For more
information, see the section on PCB Diagnostics Diagnostics and Troubleshooting
The module provides information on diagnostics and troubleshooting in the following
forms:
? LED status indicators on the front of the module provide information on the module’s
status.
? Status data contained in the module can be viewed in ProSoft Configuration Builder
through the Ethernet port.
? Status data values are transferred from the module to the processor.