GE 04220FL11232A控制器,04220FL11232A如何使用
安裝說明本節包括:? 在04220FL11232A上安裝IndustryPack(IPs)? 在VME機箱中安裝MVME172LX? 與安裝相關的系統注意事項。確保根據需要安裝EPROM設備。確保所有收割臺跳線根據需要進行配置。04220FL11232A的IP安裝04220FL11232A上最多可安裝兩個IP模塊。安裝04220FL11232A上的IP如下:1.每個IP模塊有兩個50針連接器,插入兩個MVME172LX上對應的50針連接器:J5/J6,J7/J8。MVME172LX連接器位置見圖2-1。
GE 04220FL11232A控制器–調整儀表板模塊的方向,使錐形連接器外殼匹配正確地將IP_a插入連接器J5和J6;將IP_b插入J7和J8。如果使用雙倍大小的IP,請將IP_ab插入J5、J6、J7、,和J8。2.后面提供兩個額外的50針連接器(J3和J4)用于外部電纜連接的MVME172LX前面板IP模塊。之間存在一對一的對應關系電纜連接器上的信號和相關IP連接器(即J4具有與J5相同的IP_a信號;J3具有與J7相同的IP_b信號)。–根據需要將用戶提供的50針電纜連接到J3和J4。因為對每種不同類型的摩托羅拉不提供這些電纜。–將IP電纜從MVME172LX的窄槽中取出前面板并將其連接到相應的外部設備,取決于特定IP MVME172LX安裝的性質安裝了EPROM和IP模塊并正確配置了標頭,按照以下步驟在VME機箱中安裝MVME172LX:1、關閉所有設備電源,斷開電源線來自交流電源。
通電時插入或卸下模塊可能會導致模塊組件損壞。這臺設備。在搬運、測試、,和調整。2.按照用戶手冊中的說明卸下機箱蓋設備3.將填充板從要插入的卡槽中卸下安裝MVME172LX。
Installation Instructions
This section covers:
? Installation of IndustryPacks (IPs) on the MVME172LX
? Installation of the MVME172LX in a VME chassis
? System considerations relevant to the installation. Ensure that
EPROM devices are installed as needed. Ensure that all header
jumpers are configured as desired.
IP Installation on the MVME172LX
Up to two IP modules may be installed on the MVME172LX. Install the
IPs on the MVME172LX as follows:
1. Each IP module has two 50-pin connectors that plug into two
corresponding 50-pin connectors on the MVME172LX: J5/J6,
J7/J8. See Figure 2-1 for the MVME172LX connector locations.
– Orient the IP module(s) so that the tapered connector shells mate
properly. Plug IP_a into connectors J5 and J6; plug IP_b into J7
and J8. If a double-sized IP is used, plug IP_ab into J5, J6, J7,
and J8.
2. Two additional 50-pin connectors (J3 and J4) are provided behind
the MVME172LX front panel for external cabling connections to
the IP modules. There is a one-to-one correspondence between the
signals on the cabling connectors and the signals on the associated
IP connectors (i.e., J4 has the same IP_a signals as J5; J3 has the
same IP_b signals as J7).
– Connect user-supplied 50-pin cables to J3 and J4 as needed.
Because of the varying requirements for each different kind of
IP, Motorola does not supply these cables.
– Bring the IP cables out the narrow slot in the MVME172LX
front panel and attach them to the appropriate external
equipment, depending on the nature of the particular IP(s)MVME172LX Installation
With EPROMs and IP modules installed and headers properly configured,
proceed as follows to install the MVME172LX in the VME chassis:
1. Turn all equipment power OFF and disconnect the power cable
from the AC power source.