3BHE014105R0001 5SXE08-0166變頻器可控硅模塊編程器連接,并行對于并行接口(僅限MS-DOS編程器)編程器連接到總線上的頂部端口發(fā)射器模塊(IC697BEM713)。參考參考文獻1有關(guān)編程功能的描述,請參閱串行端口15針D接頭提供與CPU上的RS-485兼容串行端口(見圖3)。此端口提供到工作站的串行連接安裝在編程計算機中的接口板。串行連接也可以通過串行CPU上的端口到編程上的串行端口計算機或其他串行設(shè)備RS-422/RS-485至RS-232轉(zhuǎn)換器(IC690ACC900)或RS-232至RS-422微型轉(zhuǎn)換器(IC690ACC901)。這可以使用可用的電纜進行連接,也可以使用可能會建造電纜以滿足您的特定需求應(yīng)用有關(guān)更多信息,請參閱參考3串行通信。有關(guān)TMR配置的更多詳細信息系統(tǒng)和PLC之間的通信在系統(tǒng)中,指模塊化冗余靈活三重模塊冗余(TMR)系統(tǒng)用戶手冊。程序員連接,以太網(wǎng)TCP/IP通過以太網(wǎng)TCP/IP連接程序員網(wǎng)絡(luò)需要安裝以太網(wǎng)接口PLC中的模塊。這可以是以太網(wǎng)控制器、IC697CMM741或以太網(wǎng)接口(類型2) ,IC697CMM742。在連接之前
The module should power up and the top LED should
blink. When the diagnostics have completed
successfully, the top LED stays on and the second and
third LEDs are off. The fourth LED is off if the
keyswitch is in the OFF position. The CPU is now
ready to be programmed (if connected parallel, the CPU
can be programmed regardless of key position). After
the program has been verified the toggle switch can be
moved to the appropriate operation mode position.
The LEDs indicate the position of the toggle switch,
memory protection status, and the state of the program.
Programmer Connection, Parallel
For a parallel interface (MS-DOS programmer only) the
programmer is connected to the top port on the Bus
Transmitter Module (IC697BEM713). Consult Reference
1 for a description of programming functionsSerial Port
The 15-pin D-connector provides the connection to an
RS-485 compatible serial port on the CPU (see Figure 3).
This port provides a serial connection to a Work Station
Interface board installed in the programming computer.
The serial connection can also be made from the serial
port on the CPU to the serial port on the programming
computer, or other serial device, through the
RS-422/RS-485 to RS-232 Converter (IC690ACC900) or
RS-232 to RS-422 Miniconverter (IC690ACC901). This
connection can be made with available cables or you
may build cables to fit the needs of your particular
application. See reference 3 for more information on
serial communications.For more detailed information on configuration of TMR
systems and communications between PLCs in thesystem, refer to the Modular Redundancy Flexible Triple
Modular Redundant (TMR) System User’s Manual.
Programmer Connection, Ethernet TCP/IP
Connecting your programmer via an Ethernet TCP/IP
network requires installation of an Ethernet Interface
module in the PLC. This can be either the Ethernet
Controller, IC697CMM741, or Ethernet Interface (Type
2), IC697CMM742. Before connecting your