FOXBORO FBM201 P0914SQ電阻輸入分壓器編程
當這些字段中的任何一個被寫入(通過單個32位寫入或單獨的16位寫入)時,無論定時器是啟用還是禁用,相應(yīng)的定時器都會在定時器時鐘的下一個上升沿加載寫入值。存儲在該寄存器中的值也會在計時器的終端計數(shù)(或超時)時自動重新加載。計時器3加載計數(shù)寄存器(TMRLCR3)計時器3為32位寬,并從計時器3加載計數(shù)器寄存器(TMLCR3)獲得其加載計數(shù),該寄存器位于BAR2中地址的偏移0x14處。此寄存器中的位映射如下:寫入此字段時,無論計時器是啟用還是禁用,計時器3都會在計時器時鐘的下一個上升沿加載寫入值。存儲在該寄存器中的值也會在計時器的終端計數(shù)(或超時)時自動重新加載。計時器4加載計數(shù)寄存器(TMRLCR4)計時器4為32位寬,并從位于BAR2中地址偏移0x18處的計時器4加載計數(shù)器寄存器(TMLCR4)中獲取其加載計數(shù)。此寄存器中的位映射如下:寫入此字段時,無論計時器是啟用還是禁用,計時器4都會在計時器時鐘的下一個上升沿加載寫入值。存儲在該寄存器中的值也會在計時器的終端計數(shù)(或超時)時自動重新加載。
When either of these fields are written (either by a single 32-bit write or separate
16-bit writes), the respective timer is loaded with the written value on the next rising
edge of the timer clock, regardless of whether the timer is enabled or disabled. The
value stored in this register is also automatically reloaded on terminal count (or
timeout) of the timer.
Timer 3 Load Count Register (TMRLCR3)
Timer 3 is 32-bits wide and obtains its load count from the Timer 3 Load Count
Register (TMRLCR3), located at offset 0x14 from the address in BAR2. The mapping
of bits in this register are as follows:When this field is written, Timer 3 is loaded with the written value on the next rising
edge of the timer clock, regardless of whether the timer is enabled or disabled. The
value stored in this register is also automatically reloaded on terminal count (or
timeout) of the timer.Timer 4 Load Count Register (TMRLCR4)
Timer 4 is 32-bits wide and obtains its load count from the Timer 4 Load Count
Register (TMRLCR4), located at offset 0x18 from the address in BAR2. The mapping
of bits in this register are as follows:
When this field is written, Timer 4 is loaded with the written value on the next rising
edge of the timer clock, regardless of whether the timer is enabled or disabled. The
value stored in this register is also automatically reloaded on terminal count (or
timeout) of the timer.