MOOG DS2000XP控制器驅動程序
PQM脈沖輸入(單位):此參數是PQM脈沖輸出將計數的基本單位的名稱。它僅用作標簽,與脈沖輸入的操作無關。5.PQM脈沖輸入1/2/3/4值:這是由開關輸入確定的分配給每個計數操作的值。6.PQM總計脈沖輸入:此參數創(chuàng)建配置的各種脈沖輸入的求和寄存器。可將其配置為用作脈沖輸入的PQM開關輸入的任何組合。使用KYZ端子的脈沖啟動器應用PQM脈沖輸入:根據接收器類型,典型的終端接收器需要KY或KZ之間的觸點閉合。由于PQM開關輸入的多功能參數,PQM開關輸出未作為專用脈沖輸入設備標記KYZ標記。然而,PQM仍然可以用作脈沖計數器。
PQM Pulse Input (Units): This parameter is the name given to the base units that the PQM Pulse Input(s) will be counting. It is used as a label only and has no bearing on the operation of the Pulse Input. 5. PQM Pulse Input 1/2/3/4 Value: This is the value assigned to each counting operation as determined by the Switch Input. 6. PQM Totalized Pulse Input: This parameter creates a summing register of the various Pulse Inputs configured. It can be configured for any combination of the PQM Switch Inputs used as Pulse Inputs. Application of the PQM Pulse Input(s) With a Pulse Initiator Using KYZ Terminals: Typical end receivers require a contact closure between KY or KZ based upon the type of receiver. Because of the multi-functional parameters of the PQM Switch Inputs, the PQM Switch Inputs are not labeled with KYZ markings as a dedicated pulse input device. However, the PQM can still be used as a pulse counter.