国产精品久久二区二区,熟女少妇内射日韩亚洲,久久亚洲国产成人精品无码区,GOGO熟女少妇大尺度

您的瀏覽器版本過低,為保證更佳的瀏覽體驗,請點擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設備有限公司網站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

HIEE450964R0001 SA9923A-E DCS模塊卡件,輸出卡件

HIEE450964R0001 SA9923A-E DCS模塊卡件,輸出卡件

HIEE450964R0001 SA9923A-E DCS模塊卡件,輸出卡件//已禁用。啟用模塊中斷報告后,此參數控制過熱模塊故障的中斷。范圍類型禁用電流設置要用于每個通道的輸出類型。選項包括:禁用電壓、禁用電流、電流/電壓。量程(僅適用于量程型電流/電壓)-10 Vdc至+10 Vdc電流/電壓:-10 Vdc至+10 Vdc,0 Vdc至+0 Vdc,4mA至20 mA,0mA至20毫安。信道...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

HIEE450964R0001 SA9923A-E DCS模塊卡件,輸出卡件

    HIEE450964R0001 SA9923A-E DCS模塊卡件,輸出卡件

    //已禁用。啟用模塊中斷報告后,此參數控制過熱模塊故障的中斷。范圍類型禁用電流設置要用于每個通道的輸出類型。選項包括:禁用電壓、禁用電流、電流/電壓。量程(僅適用于量程型電流/電壓)-10 Vdc至+10 Vdc電流/電壓:-10 Vdc至+10 Vdc,0 Vdc至+0 Vdc,4mA至20 mA,0mA至20毫安。信道值格式32位浮點16位整數或32位浮點PACSystems*RX3i系統手冊第12節GFK-2314T 2019年9月模擬輸出模塊475模塊參數(續)輸出默認值默認值控制輸出將設置為輸出禁用模式(停止)的狀態,如果發生故障,如果斷電,或如果配置已清除。選項為“保持最后狀態”,或默認為特定配置的默認值。10.4.5.1.3量程類型應為電流/電壓配置將要使用的模塊上的每個通道。然后可以根據需要配置其電壓或電流范圍和其他參數。如果不使用通道輸出且未連接,請選擇“禁用”選項。如果通道被禁用,則無需配置其任何其他參數。如果通道連接到電流輸出,但未使用,請選擇“禁用電流”。這將將該通道的輸出電流設置為0mA(該通道的電壓將為非零)。如果通道連接到電壓輸出,但未使用,請選擇“禁用電壓”。這將將該通道的輸出電壓設置為0V(該通道的輸入電流將為非零)。10.4.5.1.4輸出默認值如果啟用“保持最后狀態”,則當CPU指示“輸出未啟用”時,或如果出現下列故障之一,輸出將保持其最后命令值。如果禁用“保持最后狀態”,則命令輸出變為“默認值”。必須在選定的輸出范圍內設置默認值。如果“默認值”(Default Value)和“漸變速率”(Ramp Rate)均已啟用,則通道將漸變為默認值。故障條件為:? CPU輸出未啟用。? 背板電源不正常。在這種情況下,即使已啟用斜坡,也沒有斜坡。? 失去與CPU的通信。? I/O通信丟失。? 磁場功率損失。輸出默認注釋? 在I/O啟用模式下熱移除模塊將導致所有輸出保持最后狀態(甚至配置為強制默認值的通道)。如果不需要該操作,則可通過首先關閉現場電源并在熱卸下模塊之前卸下該模塊的接線板,將輸出強制設置為默認值。PACSystems*RX3i系統手冊第12節GFK-2314T 2019年9月模擬輸出模塊476? 即使配置了默認值,使用SVC_REQ 24重置模塊也會導致所有通道保持最后狀態。應用程序必須在執行Service Request之前處理輸出默認值。? 如果電源的背板電源丟失,則忽略默認斜坡速率配置。為“默認值”配置的通道立即變為默認值。背板電源恢復后首次存儲配置時,不使用默認斜坡速率。為“默認值”配置的任何通道都會立即變為其默認值。 Disabled. With Module Interrupt Reporting enabled, this parameter controls interrupts for Over-temperature module faults. Range Type Disabled Current Sets up the type of output to be used for each channel. Choices are: Disabled Voltage, Disabled Current, Current/Voltage. Range (Only for Range Type Current/Voltage) -10 Vdc to +10 Vdc For Current/Voltage: -10 Vdc to +10 Vdc, 0 Vdc to +10 Vdc, 4mA to 20 mA, 0mA to 20 mA. Channel Value Format 32-bit Floatingpoint 16-bit integer or 32-bit floating-point PACSystems* RX3i System Manual Section 12 GFK-2314T Sept. 2019 Analog Output Modules 475 Module Parameters (Continued) Outputs Default Force to Default Value Controls the state the output will be set to in Outputs Disabled mode (stop), if a fault occurs, if power is lost, or if the configuration is cleared. Choices are Hold Last State, or default to a specific configured default value. 10.4.5.1.3 Range Type Each channel on the module that will be used should be configured for Current/Voltage. Its voltage or current range and other parameters can then be configured as needed. If the channel output will not be used and is not wired, select either “Disabled” option. If a channel is disabled, it is not necessary to configure any of its other parameters. If the channel is wired to a current output, but is not being used, select "Disabled Current". This will set the output current of that channel to 0mA (the output voltage of that channel will be non-zero). If the channel is wired to a voltage output, but is not being used, select "Disabled Voltage". This will set the output voltage of that channel to 0V (the output current of that channel will be non-zero). 10.4.5.1.4 Output Defaults If Hold Last State is enabled, an output will hold its last commanded value when the CPU indicates Outputs Not Enabled, or if one of the fault conditions listed below occurs. If Hold Last State is disabled, the output is commanded to go to the Default Value. The Default Value must be set within the selected output range. If both Default Value and Ramp Rate are enabled, the channel will ramp to the default value. Fault conditions are: ? CPU outputs are not enabled. ? Backplane power is not ok. In that case, there is no ramping, even if ramping has been enabled. ? Loss of communications from CPU. ? Loss of I/O communications. ? Loss of field power. Outputs Default Notes ? Hot Removal of the module in an I/O Enabled mode will cause all outputs to Hold Last State (even channels configured for Force to Default Value). If that operation is not desirable, the outputs can be forced to default by first turning off field power and removing the Terminal Block of this module before hot-removing the module. PACSystems* RX3i System Manual Section 12 GFK-2314T Sept. 2019 Analog Output Modules 476 ? Resetting the module using SVC_REQ 24 causes all channels to Hold Last State even if Default Value is configured. The application program must handle output defaulting before execution of the Service Request. ? Default Ramp Rate configuration is ignored if backplane power from the power supply is lost. Channels configured for Default Value go to the default value immediately. The first time a configuration is stored following a return of backplane power, the Default Ramp rate is not used. Any channel configured for Default Value goes to its default value immediately.

    CI627.jpg

    FOXBORO H92A0K9V0H00.jpg

    18.jpg

    17.jpg



    品牌: HIMA

    型號:HIEE450964R0001 SA9923A-E 

    質保:365天

    成色:全新/二手

    發貨方式:快遞發貨


圖片名 客服

在線客服 客服一號