国产精品久久二区二区,熟女少妇内射日韩亚洲,久久亚洲国产成人精品无码区,GOGO熟女少妇大尺度

您的瀏覽器版本過低,為保證更佳的瀏覽體驗,請點擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設備有限公司網站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:xiamen2018@foxmail.com

ABB >>

A-B>>

GE>>

BENTLY>>

HIMA F3212A機器人模塊卡件

HIMA F3212A機器人模塊卡件

HIMA F3212A機器人模塊卡件0 mA對應于0的計數,20 mA對應于32000的計數。在4至20 mA和0至20 mA范圍內,可提供完整的12位分辨率。還可以配置4至20 mA增強范圍。在該范圍內,0 mA對應于-8000的計數,4 mA對應于0(零)的計數,20 mA對應于+32000的計數。可設置低報警限值以檢測4 mA至0 mA的輸入電流,從而在4至20 mA的應用中提供開路故障檢測...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

HIMA F3212A機器人模塊卡件

    HIMA F3212A機器人模塊卡件

    0 mA對應于0的計數,20 mA對應于32000的計數。在4至20 mA和0至20 mA范圍內,可提供完整的12位分辨率。還可以配置4至20 mA增強范圍。在該范圍內,0 mA對應于-8000的計數,4 mA對應于0(零)的計數,20 mA對應于+32000的計數。可設置低報警限值以檢測4 mA至0 mA的輸入電流,從而在4至20 mA的應用中提供開路故障檢測。4電流(mA)4至20mA范圍0 20 0 0至20mA范圍縮放數據單位(十進制)4000圖281:輸入縮放ALG233模擬值在轉換器范圍內縮放。工廠校準將每位模擬值(分辨率)調整為滿量程的倍數(4μa/位)。此校準使正常的12位轉換器具有4000個計數(通常212=4096個計數)。數據在模擬范圍內以4000個計數進行縮放。數據的比例如上所示。9.9.5.4變化率警報PACSystems*RX3i系統手冊第10節GFK-2314T 2019年9月模擬輸入模塊404 ALG233可檢測每秒工程單位的負變化率和正變化率。當任何一個“變化率”參數配置為非零時,模塊將取上一個樣本和當前樣本之間的工程單位差,然后除以樣本之間的經過時間。如果工程單位從上一個樣本到當前樣本的變化為負值,則模塊將比率變化與負值變化率參數進行比較。如果樣本之間的工程單位變化為正值,則模塊將比率變化與正值變化率參數值進行比較。在任何一種情況下,如果變化率大于配置的變化率,則會發生變化率警報。模塊在報警后采取的行動取決于已在診斷報告啟用和故障報告啟用參數中設置的已啟用變化率行動。變化率采樣率參數確定模塊比較變化率的頻率。可用于此參數的最小值為60ms,即,模塊可在每60ms后比較變化率。當CPU轉換到RUN模式或模塊現場電源循環時,ALG233在啟動變化率檢測前等待100ms。這是為了忽略輸入信號中的任何毛刺。9.9.5.5模塊狀態數據:ALG233 9.9.5.6信道輸入數據:ALM233模塊以其配置的輸入字報告其信道輸入數據,從其分配的信道開始0 mA corresponds to a count of 0 and 20 mA corresponds to a count of 32000. Full 12-bit resolution is available over the 4 to 20 mA and 0 to 20 mA ranges. 4 to 20 mA Enhanced range can also be configured. In that range, 0 mA corresponds to a count of -8000, 4 mA corresponds to a count of 0 (zero) and 20 mA corresponds to a count of +32000. A low alarm limit can be set up to detect input current from 4 mA to 0 mA, providing open-wire fault detection in 4 to 20 mA applications. 4 Current (mA) 4 to 20mA Range 0 20 0 0 to 20mA Range Scaled Data Units (decimal) 4000 Figure 281: Input Scaling ALG233 Analog values are scaled over the range of the converter. Factory calibration adjusts the analog value per bit (resolution) to a multiple of full scale (4 μA/bit). This calibration leaves a normal 12-bit converter with 4000 counts (normally 212 = 4096 counts). The data is scaled with the 4000 counts over the analog range. The data is scaled as shown above. 9.9.5.4 Rate of Change Alarms PACSystems* RX3i System Manual Section 10 GFK-2314T Sept. 2019 Analog Input Modules 404 The ALG233 can detect both Negative Rate of Change and Positive Rate of Change in Engineering Units per Second. When either of the Rate of Change parameters is configured to be non-zero, the module takes the difference in Engineering Units between the previous sample and the current sample, then divides by the elapsed time between samples. If the Engineering Unit change from the previous sample to current sample is negative, the module compares the rate change with the Negative Rate of Change parameter. If the Engineering Unit change between samples is positive, the module compares the rate change with the Positive Rate of Change parameter value. In either case, if the rate of change is greater than the configured rate, a rate of change alarm occurs. The actions taken by the module following the alarm depend on the enabled rate of change actions that have been set up in the Diagnostic Reporting Enable and Fault Reporting Enable parameters. The Rate of Change Sampling Rate parameter determines how frequently the module compares the Rate of Change. The minimum value which can be used with this parameter is 60 ms i.e., the module can compare the rate of change after every 60 ms. When the CPU transitions to RUN mode or the module field power is cycled, the ALG233 waits 100ms before starting Rate of Change detection. This is to ignore any glitches in the input signal. 9.9.5.5 Module Status Data: ALG233 9.9.5.6 Channel Input Data: ALG233 The module reports its channel input data in its configured input words, beginning at its assigned Channel

    2023.1.11.jpg

    2023.1.5.jpg

    手機輪播圖2(1)_副本.jpg

    公司簡介_副本.jpg



    品牌: HIMA

    型號:HIMA F3212A 

    質保:365天

    成色:全新/二手

    發貨方式:快遞發貨


圖片名 客服

在線客服 客服一號