HIMA F3215A自動(dòng)化模塊備件
模塊級(jí)診斷報(bào)告禁用(默認(rèn))或啟用如果啟用,則為每個(gè)活動(dòng)通道分配32位數(shù)據(jù)。診斷報(bào)告和故障報(bào)告可分別為每個(gè)通道啟用。PACSystems*RX3i系統(tǒng)手冊(cè)第10節(jié)GFK-2314T 2019年9月模擬輸入模塊400 9.9.5.2信道配置參數(shù):ALG233參數(shù)選擇描述范圍4-20 mA(默認(rèn)值)、0-20 mA或4-20 mA+(增強(qiáng)型)在4-20 mA范圍內(nèi),4至20 mA的輸入電流以0至32000單位的值報(bào)告給CPU。在0至20mA范圍內(nèi),0至20mA的輸入電流以0至3200單位的值報(bào)告給CPU。在4至20 mA增強(qiáng)范圍內(nèi),4至20毫安的電流以0至32000單位的值報(bào)告給CPU。低于4 mA的電流報(bào)告為負(fù)值,0表示為–8000單位。通道值格式32位浮點(diǎn)(默認(rèn)值)或16位整數(shù)32位浮點(diǎn):一個(gè)實(shí)值,范圍為3.40282e+38到3.40282e+38 16位整數(shù):32位通道數(shù)據(jù)的低位字包含16位整數(shù)通道值。高位字包含16位整數(shù)的符號(hào)。如果16位整數(shù)結(jié)果為負(fù),則32位通道數(shù)據(jù)中的高位字設(shè)置為0xFFFF。如果16位整數(shù)結(jié)果為正,則將高位字設(shè)置為0x0000。當(dāng)通道值格式參數(shù)設(shè)置為16位整數(shù)時(shí),1000工程單位等于1.0 A/D單位。高標(biāo)度值(工程單位)四個(gè)標(biāo)度參數(shù)的默認(rèn)值和范圍取決于配置的范圍類(lèi)型和信道值格式。如果:高量程工程單位=高量程A/D單位,低量程工程單位/低量程A/D單位時(shí),則禁用縮放。默認(rèn)值為所選范圍類(lèi)型的A/D上限。當(dāng)通道值格式設(shè)置為32位浮點(diǎn)時(shí),范圍為-3.40282e+38至3.40282e+38。對(duì)于16位整數(shù),范圍為-32768到+32767。低量程值(英制單位)高量程值(A/D單位)低量程值)正變化率極限(英制單位/秒)范圍:0.0(默認(rèn)值)至3.40282e+38工程單位每秒變化率,將觸發(fā)正變化率報(bào)警。如果設(shè)置為0,則禁用限制。與“采樣率變化率”參數(shù)一起使用。PACSystems*RX3i系統(tǒng)手冊(cè)第10節(jié)GFK-2314T 2019年9月模擬輸入模塊401負(fù)變化率限值(英制單位/秒)范圍:0.0(默認(rèn)值)至3.40282e+38工程單位/秒變化率,將觸發(fā)負(fù)變化率報(bào)警。如果設(shè)置為0,則禁用限制。與“采樣率變化率”參數(shù)一起使用。變化率采樣率(秒)0.0(默認(rèn)值)到300.0比較之間等待的時(shí)間從0到300秒。如果設(shè)置為默認(rèn)值0.0,模塊將在每個(gè)輸入樣本后進(jìn)行檢查。PACSystems*RX3i系統(tǒng)手冊(cè)第10節(jié)GFK-2314T 2019年9月模擬輸入模塊402信道參數(shù)(續(xù))參數(shù)選擇描述高高報(bào)警(英制單位)這些參數(shù)的默認(rèn)值和范圍取決于配置的范圍和信道值格式。報(bào)警和死區(qū)所有報(bào)警參數(shù)均在工程單位中指定。要使用報(bào)警,必須啟用診斷報(bào)告或故障報(bào)告。高-高
Module Level Diagnostic Reporting Disabled (default) or Enabled If enabled, 32 bits of data are allocated for each active channel. Diagnostic Reporting and Fault Reporting can be enabled separately for each channel. PACSystems* RX3i System Manual Section 10 GFK-2314T Sept. 2019 Analog Input Modules 400 9.9.5.2 Channel Configuration Parameters: ALG233 Parameter Choices Description Range 4-20 mA (default), 0-20 mA, or 4-20 mA + (enhanced) In the 4-20 mA range, input currents from 4 to 20 mA are reported to the CPU as values from 0 to 32000 units. In the 0 to 20 mA range, input currents from 0 to 20 mA are reported to the CPU as values from 0 to 3200 units. In the 4 to 20 mA enhanced range, currents from 4 to 20 mA are reported to the CPU as values from 0 to 32000 units. Currents below 4 mA are reported as negative values with 0 represented as –8000 units. Channel Value Format 32-bit Floatingpoint (default) or 16-bit Integer 32-bit Floating-point: A real value, range 3.40282e+38 through 3.40282e+38 16-bit Integer: The low word of the 32-bit channel data contains the 16-bit integer channel value. The high word contains the sign of the 16-bit integer. If the 16-bit integer result is negative, the upper word in the 32-bit channel data is set to 0xFFFF. If the 16-bit integer result is positive, the upper word is set to 0x0000. When the Channel Value Format parameter is set to 16- bit Integer, 1000 Eng Units are equal to 1.0 A/D Unit. High Scale Value (Eng Units) The defaults and ranges for the four scaling parameters depend on the configured Range Type and Channel Value Format. Scaling is disabled if: High Scale Eng. Units = High Scale A/D Units and Low Scale Eng. Units = Low Scale A/D Units. Default is High A/D Limit of selected range type. When Channel Value Format is set to 32-bit Floatingpoint, range is -3.40282e+38 through 3.40282e+38. For 16-bit Integer, range is -32,768 through +32,767. Low Scale Value (Eng Units) High Scale Value (A/D Units) Low Scale Value (A/D Units) Positive Rate of Change Limit (Eng Units/Second) Range: 0.0 (default) through 3.40282e+38 Rate of change in Engineering Units per Second that will trigger a Positive Rate of Change alarm. If set to 0, limit is disabled. Used with “Rate of Change Sampling Rate” parameter. PACSystems* RX3i System Manual Section 10 GFK-2314T Sept. 2019 Analog Input Modules 401 Negative Rate of Change Limit (Eng Units/Second) Range: 0.0 (default) through 3.40282e+38 Rate of change in Engineering Units per Second that will trigger a Negative Rate of Change alarm. If set to 0, limit is disabled. Used with “Rate of Change Sampling Rate” parameter. Rate of Change Sampling Rate (Seconds) 0.0 (default) through 300.0 Time from 0 through 300 seconds to wait between comparisons. If set to the default value of 0.0, the module checks after every input sample. PACSystems* RX3i System Manual Section 10 GFK-2314T Sept. 2019 Analog Input Modules 402 Channel Parameters (Continued) Parameter Choices Description High-High Alarm (Eng Units) The defaults and ranges for these parameters depend on the configured Range and Channel Value Format. Alarms and Deadbands All of the alarm parameters are specified in Engineering Units. To use alarming, Diagnostic Reporting or Fault Reporting must be enabled. High-High