模擬輸出模塊用戶負載COM OUT COM OUT屏蔽僅在模塊端連接端子排外殼GND可選接地連接接地用戶負載圖46:模擬輸出屏蔽接地,帶端子排PACSystems*RX3i系統手冊第3節GFK-2314T 2019年9月安裝62 2.6.4.11模塊保險絲列表警告僅更換正確尺寸和類型的保險絲。使用不正確的保險絲可能會導致人員傷害、設備損壞或兩者兼而有之。模塊目錄號(注)模塊類型額定電流模塊GE保險絲零件號其他來源和零件號IC694MDL3103 120 Vac、0.5A 3A 2 44A724627-111 Bussman–GMC-3 Littlefuse–239003 IC694MDL303 120/240 Vac、1A 5A 2 42G6101-0013 Bussman-S506-5-R Schurter-034.3124 IC694ML3403 120 Vac,0.5A 3A 2 44A724627-111 Bussman–GMC-3 Littlefuse–239003 IC694MDL3903 120/240 Vac,2A 3A 5 44A724627-111 Bussman-GMC-3 Littlefuse-239003 IC6914PWR3214 IC694PWR3304 120/240 Vac或125Vdc輸入,30 W電源2A 1 44A724627 109 Bussman?215-002(GDC-2或GMC-2)Littlefuse-239-002 IC694PWR 3314 24Vdc輸入,30 W電源5A 1 44A724627-114 Bussman–GMC-5-R 3保險絲安裝在夾子中,從模塊外殼上拆下電路板即可接近。4電源輸入保險絲安裝在夾子中,可通過拆下模塊的前部進行操作。PACSystems*RX3i系統手冊第3節GFK-2314T 2019年9月安裝63 2.6.5 CPU安裝:安裝CPU:1。確保機架電源已關閉。將CPU模塊安裝在適當的插槽中(請參閱通用背板插槽占用規則,第2.6.1.3節)。除CPE302/CPE305外,CPU占用兩個插槽,可以使用除編號最高(最右邊)插槽之外的任何插槽。CPE302/CPE305占用一個插槽。3.打開電源。當CPU成功完成初始化時,OK(正常)指示燈保持亮起,RUN(運行)和EN(運行)指示燈熄滅。CPU現在可以編程了。4.對于帶備用電池的CPU,將電池連接到模塊上的任一電池連接器。(您可以在安裝過程中的任何步驟連接電池,但除非通電,否則電池會立即耗盡。為了最大限度地延長電池壽命,請在打開電源后安裝電池)。5.對于由Energy Pack備份的CPU,請遵循特定Energy Pack的安裝說明。6.在適當的情況下,通信電纜可以固定在模塊底部的系緊裝置上。驗證程序后,可將模式開關移至適當的操作模式位置:RUN I/O ENABLED(運行輸入/輸出啟用)、RUN OUTPUT DISABLE(運行輸出禁用)或STOP(停止)。LED指示燈指示模式開關的位置和串行端口活動的狀態。圖47:CPE330(2插槽CPU示例)注意:CPU不能熱插入背板;在安裝或卸下CPU之前,必須斷開電源。PACSystems*RX3i系統手冊第3節GFK-2314T 2019年9月安裝64 2.6.6電源。將電源模塊安裝到相應的插槽中。a) 通用電源(IC695)可以安裝在通用背板中編號最高(最右邊)的插槽以外的任何插槽中。b) 擴展電源(IC694)必須安裝在擴展背板的電源(最左側)插槽中。c) 如果要使用多個電源,請參閱第2.6.1.2)2節“電源型號和插槽占用”。按照特定電源的安裝說明將接線連接到電源。3.安裝后,使用模塊底部的三個接線系緊裝置固定電源和接地線。電源P/S故障超溫過載電源40W AC PACSystems? RX3i圖48:典型RX3i電源模塊警告對于所有電源,如果使用同一輸入電源為系統中的兩個或多個電源供電,則每個電源的連接極性必須相同。由此產生的電位差可能會傷害人員或損壞設備。此外,每個背板必須連接到公共系統接地。PACSystems*RX3i系統手冊第3節GFK-2314T 2019年9月安裝65 2.6.6.1電源現場接線? 對于IC695電源,每個端子接受一根AWG#14至AWG#22導線。圖49(下圖)是IC695電源上一個端子的橫截面圖。每條電線的末端應至少剝開3/8英寸(9mm)。端子可接受剝開至11 mm(.433 in)的導線,同時提供絕緣體的完全固定。電線必須完全插入接線盒,如圖49左側所示,以使絕緣滿足端子內部的絕緣停止位置。擰緊端子螺釘,使夾具牢固地抵住導線的剝皮端,將其固定到位。如果電線未完全插入,如右圖所示,擰緊夾子可能會將電線向上推,從而使其無法連接。
Analog Output Module User Load COM OUT COM OUT Shields Connected at module end only Terminal Strip Enclosure GND Optional Ground Connection Earth Ground User Load Figure 46: Analog Output Shield Grounding with a Terminal Strip PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 62 2.6.4.11 Module Fuse List WARNING Replace fuse only with the correct size and type. Using an incorrect fuse can result in harm to personnel, damage to equipment, or both. Module Catalog Number (note) Module Type Current Rating Quantity on Module GE Fuse Part Number Other Sources and Part Numbers IC694MDL3103 120 Vac, 0.5A 3A 2 44A724627-111 Bussman – GMC-3 Littlefuse – 239003 IC694MDL3303 120/240 Vac, 1A 5A 2 42G6101-0013 Bussman - S506-5-R Schurter - 034.3124 IC694MDL3403 120 Vac, 0.5A 3A 2 44A724627-111 Bussman – GMC-3 Littlefuse – 239003 IC694MDL3903 120/240 Vac, 2A 3A 5 44A724627-111 Bussman – GMC-3 Littlefuse – 239003 IC694PWR3214 IC694PWR3304 120/240 Vac or 125Vdc Input, 30 W Power Supply 2A 1 44A724627-109 Bussman – 215-002 (GDC-2 or GMC-2) Littlefuse – 239-002 IC694PWR3314 24Vdc Input, 30 W Power Supply 5A 1 44A724627-114 Bussman – GMC-5-R 3 Fuse is mounted in clip accessible by removing circuit board from module housing. 4 Power input fuse mounted in clip and accessible by removing front of module. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 63 2.6.5 CPU Installation ? To install the CPU: 1. Make sure that rack power is off. 2. Install the CPU module in the appropriate slot (refer to Universal Backplane Slot Occupancy Rules, Section 2.6.1.3). With the exception of CPE302/CPE305, the CPU occupies two slots and can use any slots except the highest numbered (rightmost) slot. CPE302/CPE305 occupies one slot. 3. Turn on power. When the CPU has successfully completed initialization, the OK LED stays on and the RUN and EN LEDs are off. The CPU is now ready to be programmed. 4. For CPUs with battery back-up, connect the battery to either of the battery connectors on the module. (You can connect the battery at any step in the installation process but it will begin to drain immediately unless power is applied. To maximize battery life, install it after power has been turned on). 5. For CPUs backed up by an Energy Pack, follow the installation instructions for the specific Energy Pack. 6. Where appropriate, communications cables can be secured to the tie-downs on the bottom of the module. After the program has been verified, the mode switch can be moved to the appropriate operation mode position: RUN I/O ENABLED, RUN OUTPUT DISABLE, or STOP. The LEDs indicate the position of the mode switch and status of serial port activity. Figure 47: CPE330 (example of 2-Slot CPU) CAUTION CPUs may NOT be hot-inserted in the backplane; power must be removed before installing or removing the CPU. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 64 2.6.6 Power Supplies ? To install the power supplies 1. Install the Power Supply module(s) in the appropriate slot(s). a) Universal Power Supplies (IC695) can be installed in any slot except the highest numbered (rightmost) slot in a Universal Backplane. b) Expansion Power Supplies (IC694) must be installed in the Power Supply (leftmost) slot in an Expansion Backplane. c) Where multiple power supplies are to be used, refer to Power Supply Models and Slot Occupancy, Section 2.6.1.2) 2. Connect wiring to the Power Supply per the installation instructions for that specific power supply. 3. Use the three wiring tie-downs on the bottom of the module to secure the power and ground wires after installation. POWER P/S FAULT OVERTEMP OVERLOAD Power Supply 40W AC PACSystems? RX3i Figure 48: Typical RX3i Power Supply Module WARNING For all Power Supplies, if the same input power source is used to provide power to two or more power supplies in the system, connection polarity must be identical at each power supply. A resulting difference in potential can injure personnel or cause damage to equipment. Also, each backplane must be connected to a common system ground. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 65 2.6.6.1 Power Supply Field Wiring ? For IC695 Power Supplies, each terminal accepts one AWG #14 to AWG #22 wire. Figure 49 (below) is a cross-section of one of the terminals on an IC695 Power Supply. The end of each wire should be stripped at least 3/8-inch (9mm). The terminal can accept a wire that is stripped up to 11 mm (.433 in) while providing full seating of the insulator. The wire must be fully-inserted into the terminal block as illustrated in Figure 49 at left, so that the insulation meets the insulation stop position inside the terminal. Tightening the terminal screw pivots the clamp firmly against the stripped end of the wire, holding it in place. If the wire is not fully inserted, as shown on the right, tightening the clamp may push the wire upward, so that it is not connected.