HONEYWELL TC-RPFS01工控模塊備件
塊延遲到期后,將監(jiān)控數(shù)字輸入。如果在規(guī)定的延遲后發(fā)生關(guān)閉,將發(fā)生跳閘。n ASSIGNABLE INPUT 1 n[ENTER]了解更多輸入1功能:壓力開關(guān)報警范圍:見上文。以下設(shè)定值僅在輸入1(4)功能為“壓力開關(guān)報警”BLOCK PRES.Sw時適用。啟動警報:0 s范圍:0到5000 s,步長為1(0表示電機停止運行時功能激活)。僅當(dāng)輸入1(4)功能為“壓力開關(guān)報警”時可見壓力開關(guān)報警:未鎖定范圍:鎖定,未鎖定。僅當(dāng)輸入1(4)功能為“壓力開關(guān)報警”時才可見,分配報警繼電器:報警范圍:報警、報警和輔助2、報警和輔2、報警與輔助3、報警與輔3、輔助2、輔助2和輔助3、輔助3。僅當(dāng)輸入1(4)功能為“壓力開關(guān)報警”壓力開關(guān)時可見。報警延遲:5.0秒范圍:0.1至100.0秒,步長:0.1。僅當(dāng)輸入1(4)功能為“壓力開關(guān)報警”壓力開關(guān)時可見。報警事件:關(guān)閉范圍:打開、關(guān)閉。僅當(dāng)輸入1(4)功能為“壓力開關(guān)報警”n可分配輸入1 n[ENTER]了解更多輸入1功能:壓力開關(guān)跳閘范圍:見上文。以下設(shè)定值僅在輸入1(4)功能為“壓力開關(guān)跳閘”BLOCK PRES.SW時適用。從啟動跳閘:0 s范圍:0至5000秒。;步驟:1(0表示在電機停止和運行時功能激活)。僅當(dāng)輸入1(4)功能為“壓力開關(guān)跳閘”時可見,分配跳閘繼電器:跳閘范圍:跳閘、跳閘和輔助2、跳閘和輔2和輔助3、跳閘和備用3。僅當(dāng)輸入1(4)功能為“壓力開關(guān)跳閘”壓力開關(guān)時可見。跳閘延遲:5.0 s范圍:0.1至100.0 s,步長0.1。僅當(dāng)輸入1(4)功能為“壓力開關(guān)跳閘”時,才顯示ENTER ESCAPE?MESSAGE ESCAPE MESSAGE ESCAPE MESSURE ESCAPE MESSAGE ESCAPE MESSION ESCAPE MISSAGE ESCAP MESSAGE MESSAGE ESCAPE ENTER ESCAPE?信息ESCAPE GE Multilin 469電機管理繼電器4-21 4設(shè)定點4.4 S3數(shù)字輸入4 h)振動開關(guān)報警路徑:設(shè)定點為一個可分配的數(shù)字輸入選擇振動開關(guān)報警功能,此處顯示的設(shè)置點消息將跟隨分配消息。當(dāng)電機停止或運行時,將監(jiān)控數(shù)字輸入。如果在指定的延遲后發(fā)生關(guān)閉,將發(fā)出警報。i) 振動開關(guān)跳閘路徑:設(shè)定值×S3數(shù)字輸入×可分配輸入1(4)一旦為其中一個可分配數(shù)字輸入選擇了振動開關(guān)跳閘功能,此處顯示的設(shè)定點信息將跟隨分配信息。當(dāng)電機停止或運行時,將監(jiān)控數(shù)字輸入。如果在規(guī)定的延遲后發(fā)生關(guān)閉,將發(fā)生跳閘。n ASSIGNABLE INPUT 1 n[ENTER]了解更多輸入1功能:振動開關(guān)報警范圍:見上文。以下設(shè)定值僅在輸入1(4)功能為“振動開關(guān)報警”時適用。振動開關(guān)警報:未鎖定范圍:鎖定、未鎖定。僅當(dāng)輸入1(4)功能為“振動開關(guān)報警”時才可見,分配報警繼電器:報警范圍:報警、報警和輔助2、報警和輔2、報警與輔助3、報警與輔3、輔助2、輔助2和輔助3、輔助3。僅當(dāng)輸入1(4)功能為“振動開關(guān)報警”振動開關(guān)時可見。報警延遲:5.0 s范圍:0.1至100.0 s,步長0.1。僅當(dāng)輸入1(4)功能為“振動開關(guān)報警”振動開關(guān)時可見。報警事件:關(guān)閉范圍:打開、關(guān)閉。僅當(dāng)輸入1(4)功能為“振動開關(guān)報警”n可分配輸入1 n[ENTER]了解更多輸入1功能:振動開關(guān)跳閘范圍:見上文。以下設(shè)定值僅在輸入1(4)功能為“振動開關(guān)跳閘”時適用。分配跳閘繼電器:跳閘范圍:跳閘、跳閘和輔助2、跳閘和輔2和輔3、跳閘和備用3。僅當(dāng)輸入1(4)功能為“振動開關(guān)跳閘”振動開關(guān)時可見。跳閘延遲:5.0 s范圍:0.1至100.0 s,步長0.1。僅當(dāng)輸入1(4)功能為“振動開關(guān)跳閘”時才可見,輸入ESCAPE(輸入ESCAPE)信息ESCAPE MESSAGE ESCAPE信息ESCAPE MESSAGE ESCAPE(輸出ESCAPE)信息ESCAP(輸入ESCAP(輸出ESCAP)信息)4-22 469電機管理繼電器GE Multilin 4.4 S3數(shù)字輸入4設(shè)置點4 j)數(shù)字計數(shù)器路徑:設(shè)置點×S3數(shù)字輸入×可分配輸入1(1)一旦選擇數(shù)字計數(shù)器功能對于其中一個可分配的數(shù)字輸入,此處顯示的設(shè)置點消息將跟隨分配消息。通過增加或減少計數(shù)器值,將對開關(guān)的每次閉合進行計數(shù)。當(dāng)達到某個計數(shù)時,可以配置報警。計數(shù)器值可在A4維護×通用計數(shù)器×數(shù)字計數(shù)器實際值中查看。要初始化計數(shù)器,在此處編程計數(shù)器值,然后將S1 469 SETUP(設(shè)置)×CLEAR DATA(清除數(shù)據(jù))×PRESET DIGITAL counter(預(yù)設(shè)數(shù)字計數(shù)器)設(shè)定值更改為“Yes(是)”。例如,電容式接近探頭可用于感測非磁性單元
After the block delay has expired, the digital input will be monitored. If a closure occurs, after the specified delay, a trip will occur. n ASSIGNABLE INPUT 1 n [ENTER] for more INPUT 1 FUNCTION: Pressure Sw Alarm Range: See above. The following setpoints apply only if INPUT 1(4) FUNCTION is “Pressure Sw Alarm” BLOCK PRES. SW. ALARM FROM START: 0 s Range: 0 to 5000 s in steps of 1 (0 indicates feature is active while motor is stopped as well as running). Only seen if INPUT 1(4) FUNCTION is “Pressure Sw Alarm” PRESSURE SWITCH ALARM: Unlatched Range: Latched, Unlatched. Only seen if INPUT 1(4) FUNCTION is “Pressure Sw Alarm” ASSIGN ALARM RELAYS: Alarm Range: Alarm, Alarm & Auxiliary2, Alarm & Aux2 & Aux3, Alarm & Auxiliary3, Auxiliary2, Aux2 & Aux3, Auxiliary3. Only seen if INPUT 1(4) FUNCTION is “Pressure Sw Alarm” PRESSURE SW. ALARM DELAY: 5.0 s Range: 0.1 to 100.0 sec., step: 0.1. Only seen if INPUT 1(4) FUNCTION is “Pressure Sw Alarm” PRESSURE SW. ALARM EVENTS: Off Range: On, Off. Only seen if INPUT 1(4) FUNCTION is “Pressure Sw Alarm” n ASSIGNABLE INPUT 1 n [ENTER] for more INPUT 1 FUNCTION: Pressure Switch Trip Range: See above. The following setpoints apply only if INPUT 1(4) FUNCTION is “Pressure Switch Trip” BLOCK PRES. SW. TRIP FROM START: 0 s Range: 0 to 5000 sec.; step: 1 (0 indicates feature is active while motor is stopped as well as running). Only seen if INPUT 1(4) FUNCTION is “Pressure Switch Trip” ASSIGN TRIP RELAYS: Trip Range: Trip, Trip & Auxiliary2, Trip & Aux2 & Aux3, Trip & Auxiliary3. Only seen if INPUT 1(4) FUNCTION is “Pressure Switch Trip” PRESSURE SW. TRIP DELAY: 5.0 s Range: 0.1 to 100.0 s in steps of 0.1. Only seen if INPUT 1(4) FUNCTION is “Pressure Switch Trip” ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE GE Multilin 469 Motor Management Relay 4-21 4 SETPOINTS 4.4 S3 DIGITAL INPUTS 4 h) VIBRATION SWITCH ALARM PATH: SETPOINTS ?× S3 DIGITAL INPUTS ?× ASSIGNABLE INPUT 1(4) Once the Vibration Switch Alarm function is chosen for one of the assignable digital inputs, the setpoint messages shown here will follow the assignment message. When the motor is stopped or running, the digital input will be monitored. If a closure occurs, after the specified delay, an alarm will occur. i) VIBRATION SWITCH TRIP PATH: SETPOINTS ?× S3 DIGITAL INPUTS ?× ASSIGNABLE INPUT 1(4) Once the Vibration Switch Trip function is chosen for one of the assignable digital inputs, the setpoint messages shown here will follow the assignment message. When the motor is stopped or running, the digital input will be monitored. If a closure occurs, after the specified delay, a trip will occur. n ASSIGNABLE INPUT 1 n [ENTER] for more INPUT 1 FUNCTION: Vibration Sw Alarm Range: See above. The following setpoints apply only if INPUT 1(4) FUNCTION is “Vibration Sw Alarm”. VIBRATION SWITCH ALARM: Unlatched Range: Latched, Unlatched. Only seen if INPUT 1(4) FUNCTION is “Vibration Sw Alarm” ASSIGN ALARM RELAYS: Alarm Range: Alarm, Alarm & Auxiliary2, Alarm & Aux2 & Aux3, Alarm & Auxiliary3, Auxiliary2, Aux2 & Aux3, Auxiliary3. Only seen if INPUT 1(4) FUNCTION is “Vibration Sw Alarm” VIBRATION SW. ALARM DELAY: 5.0 s Range: 0.1 to 100.0 s in steps of 0.1. Only seen if INPUT 1(4) FUNCTION is “Vibration Sw Alarm” VIBRATION SW. ALARM EVENTS: Off Range: On, Off. Only seen if INPUT 1(4) FUNCTION is “Vibration Sw Alarm” n ASSIGNABLE INPUT 1 n [ENTER] for more INPUT 1 FUNCTION: Vibration Sw Trip Range: See above. The following setpoints apply only if INPUT 1(4) FUNCTION is “Vibration Sw Trip”. ASSIGN TRIP RELAYS: Trip Range: Trip, Trip & Auxiliary2, Trip & Aux2 & Aux3, Trip & Auxiliary3. Only seen if INPUT 1(4) FUNCTION is “Vibration Sw Trip” VIBRATION SW. TRIP DELAY: 5.0 s Range: 0.1 to 100.0 s in steps of 0.1. Only seen if INPUT 1(4) FUNCTION is “Vibration Sw Trip” ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE MESSAGE ESCAPE ENTER ESCAPE e e MESSAGE ESCAPE MESSAGE ESCAPE 4-22 469 Motor Management Relay GE Multilin 4.4 S3 DIGITAL INPUTS 4 SETPOINTS 4 j) DIGITAL COUNTER PATH: SETPOINTS ?× S3 DIGITAL INPUTS ?× ASSIGNABLE INPUT 1(4) Once the Digital Counter function is chosen for one of the assignable digital inputs, the setpoint messages shown here will follow the assignment message. Each closure of the switch will be counted, by either adding or decrementing the counter value. An alarm may be configured when a certain count is reached. The counter value may be viewed in the A4 MAINTENANCE ?× GENERAL COUNTERS ?× DIGITAL COUNTER actual value. To initialize the counter, program the counter value here and then change the S1 469 SETUP ?× CLEAR DATA ?× PRESET DIGITAL COUNTER setpoint to "Yes". For example, a capacitive proximity probe may be used to sense non-magnetic units