ICS TRIPLEX T3300自動化模塊備件
或Windows 95/98。Windows 3.1用戶必須確保安裝了SHARE.EXE。469PC可從GE Multilin產品CD或GE Multilin網站安裝,網址為http://www.GEindustrial.com/multilin.如果您使用的是沒有網絡訪問或CD的傳統設備,可以從工廠訂購3.5英寸軟盤。注:GE Multilin 469電機管理繼電器3-5 3用戶界面3.2 469PC軟件界面3 3.2.2安裝/升級a)準備如果469PC已經安裝,運行程序并檢查是否需要升級,如下所示:1。在469PC運行時,插入GE Multilin Products CD并允許其自動啟動(或者,將D:\index.htm文件加載到默認的web瀏覽器中,或轉到GE Multilin網站http://www.GEindustrial.com/multilin(優選方法)。2.單擊“Software”(軟件)菜單項,然后從產品列表中選擇“469 Motor Management Relay”(469電機管理繼電器)。3.驗證此頁面上顯示的版本是否與如下所示的已安裝版本相同。選擇“幫助”>“關于469PC”菜單項以確定本地PC上正在運行的版本。806972A1.CDR如果這兩個版本不匹配,則必須升級469PC軟件。3-6 469電機管理繼電器GE Multilin 3.2 469PC軟件接口3用戶接口3 b)安裝/升級469PC 469PC軟件的安裝/升級如下:1。確保Windows正在本地PC 2上運行。將GE Multilin Products CD插入CD-ROM驅動器,或將web瀏覽器指向GE Multilin網站http://www.GEindustrial.com/multilin.對于Windows 95/98或更高版本,產品CD將自動啟動歡迎屏幕;對于Windows 3.1,通過啟動CD根目錄中的index.htm文件打開產品CD。產品CD本質上是GE Multilin網站在CD上打印日期的“快照”。因此,從CD和web安裝的程序是相同的;然而,為了確保安裝了469PC的最新版本,最好從web安裝。圖3–2:GE MULTILIN歡迎屏幕3。單擊主頁面的“按產品名稱索引”項目,然后從產品列表中選擇469 Motor Management Relay,以打開469產品頁面。4.單擊“產品資源”列表中的“軟件”項,轉到469軟件頁面。5.將顯示469PC軟件的最新版本。單擊469PC程序項將安裝程序下載到本地PC。運行安裝程序并按照提示安裝到所需目錄。完成后,將出現一個新的GE Multilin組窗口,其中包含469PC圖標。806973A1.CDR可從該菜單訪問特定資源從產品列表中選擇直接進入469電機管理繼電器產品頁面469技術出版物和469支持可通過菜單支持GE Multilin 469電機控制繼電器3-7 3用戶界面3.2 469PC軟件界面3 3.2.3啟動和通信配置1訪問。將運行469PC軟件的計算機通過一個RS485端口(詳情和接線請參見第2-18頁第2.2.11節:RS485通信端口)或直接通過RS232前端端口連接至繼電器。啟動469PC。啟動時,軟件嘗試與繼電器通信。如果通信成功建立,屏幕上顯示的繼電器將顯示與實際繼電器上相同的信息。當通信建立時,顯示的LED狀態也將與實際繼電器相匹配。3.如果469PC無法建立通信
or Windows 95/98. Windows 3.1 Users must ensure that SHARE.EXE is installed. 469PC can be installed from either the GE Multilin Products CD or from the GE Multilin website at http://www.GEindustrial.com/multilin. If you are using legacy equipment without web access or a CD, 3.5” floppy disks can be ordered from the factory. NOTE GE Multilin 469 Motor Management Relay 3-5 3 USER INTERFACES 3.2 469PC SOFTWARE INTERFACE 3 3.2.2 INSTALLATION/UPGRADE a) PREPARATION If 469PC is already installed, run the program and check if it needs upgrading as follows: 1. While 469PC is running, insert the GE Multilin Products CD and allow it to autostart (alternately, load the D:\index.htm file into your default web browser, OR Go to the GE Multilin website at http://www.GEindustrial.com/multilin (preferred method). 2. Click the “Software” menu item and select “469 Motor Management Relay” from the product list. 3. Verify that the version shown on this page is identical to the installed version as shown below. Select the Help > About 469PC menu item to determine which version is running on the local PC. 806972A1.CDR If these two versions do not match, then the 469PC software must be upgraded. 3-6 469 Motor Management Relay GE Multilin 3.2 469PC SOFTWARE INTERFACE 3 USER INTERFACES 3 b) INSTALLING/UPGRADING 469PC Installation/upgrade of the 469PC software is accomplished as follows: 1. Ensure that Windows is running on the local PC 2. Insert the GE Multilin Products CD into your CD-ROM drive or point your web browser to the GE Multilin website at http://www.GEindustrial.com/multilin. With Windows 95/98 or higher, the Products CD will launch the welcome screen automatically; with Windows 3.1, open the Products CD by launching the index.htm file in the CD root directory. The Products CD is essentially a “snapshot” of the GE Multilin website at the date printed on the CD. As such, the procedures for installation from the CD and the web are identical; however, to ensure that the newest version of 469PC is installed, installation from the web is preferred. Figure 3–2: GE MULTILIN WELCOME SCREEN 3. Click the Index by Product Name item from the main page and select 469 Motor Management Relay from the product list to open the 469 product page. 4. Click the Software item from the Product Resources list to go to the 469 software page. 5. The latest version of the 469PC software will be shown. Click on the 469PC Program item to download the installation program to your local PC. Run the installation program and follow the prompts to install to the desired directory. When complete, a new GE Multilin group window will appear containing the 469PC icon. 806973A1.CDR Specific resources can be accessed from this menu Select from the Products list to proceed directly to the 469 Motor Management Relay Product Page 469 Technical publications and support for the 469 can be accessed through the menu Support GE Multilin 469 Motor Management Relay 3-7 3 USER INTERFACES 3.2 469PC SOFTWARE INTERFACE 3 3.2.3 STARTUP AND COMMUNICATIONS CONFIGURATION 1. Connect the computer running the 469PC software to the relay via one of the RS485 ports (see Section 2.2.11: RS485 Communications Ports on page 2–18 for details and wiring) or directly via the RS232 front port. 2. Start 469PC. When starting, the software attempts to communicate with the relay. If communications are successfully established, the relay shown on the screen will display the same information seen on the actual relay The LED Status shown will also match the actual relay when communications is established. 3. If 469PC cannot establish communications