ICS TRIPLEX T7150A模擬量輸入模塊
總實際功耗范圍:0至999999.999 MW·小時。定時準確度:±0.5%更新率:5秒計量無功功耗描述:連續(xù)總無功功耗范圍:0至999999.999 Mvar·小時定時準確度±0.5%更新速率:5秒測量無功發(fā)電描述:連續(xù)無功總發(fā)電范圍:0到2000000.000 Mvar·時間定時準確度?.5%更新速率:需求量測量值:最大相電流3相實際功率3相視在功率3相無功功率測量類型:滾動需求間隔:5至90分鐘,步長為1更新率:1分鐘元素:報警其他特征跳閘前數(shù)據(jù)事件記錄器跟蹤存儲器啟動器故障模擬VT故障環(huán)境環(huán)境工作溫度:-40°C至+60°C環(huán)境儲存溫度:-40°C至+80°C濕度:高達90%,無冷凝。海拔:高達2000米污染程度:2在低于-20°C的溫度下,LCD對比度可能會受損。建議469每年至少通電一次,以防止電源中電解電容器的劣化。備用電池使用:僅當繼電器無控制電源時預期壽命:≥10年,繼電器無控制功率時外殼類型:完全抽出式(自動CT短路)密封:密封提供門:防塵門安裝:面板或19“機架安裝IP等級:IP20-X生產(chǎn)測試熱循環(huán):在環(huán)境溫度下運行測試,降低至-40°C,然后升高至60°C介電強度:2.0 kV,持續(xù)1分鐘,從繼電器、CT、VT、電源到安全接地。在任何生產(chǎn)測試期間,請勿將過濾器接地連接到安全接地線!3 3 3 3注意事項警告1-8 469電機管理繼電器GE Multilin 1.2規(guī)范第1部分簡介1類型測試介電強度:根據(jù)IEC 255-5和ANSI/IEEE C37.90 2.0 kV,從繼電器、CT、VT、電源到安全接地絕緣電阻:IEC255-5 500 V DC,從繼電器,CT、VT,電源到安全地在介電強度或絕緣電阻測試期間,不要將過濾器接地連接到安全接地線!瞬態(tài):ANSI C37.90.1振蕩(2.5kV/1MHz);ANSI C37.90.1快速上升(5kV/10ns);安大略水電A-28M-82;IEC255-4脈沖/高頻干擾,III級水平脈沖測試:IEC 255-5 0.5焦耳5 kV RFI:50 MHz/15 W發(fā)射器EMI:C37.90.2 150 MHz和450 MHz、10 V/m S鎖定位置的電磁干擾,直到電氣連接完全匹配。任何469都可以安裝在任何469機箱中,但定制制造的單元除外,這些單元在機箱和單元上都有明確標識,并且配有索引銷鍵控機構,以防止錯誤配對。裝置安裝期間無需遵守特殊通風要求。469可用濕布清潔。圖2-1:尺寸為防止未經(jīng)授權拆除抽出裝置,可在手柄上的槽中安裝導線密封。該密封件就位后,拉出裝置無法拆除。密碼或設定點訪問跳線可用于防止輸入設定點,但允許監(jiān)控實際值。如果必須限制接觸前面板控制裝置,則可在蓋子上安裝單獨的密封件,以防止其打開。如果產(chǎn)品未用于預期用途,可能會導致危險。圖2-2:拉出裝置上的密封警告2-2 469電機管理繼電器GE Multilin 2.1機械2安裝2 2.1.2產(chǎn)品標識每個469裝置和外殼都配有永久標簽。該標簽安裝在裝置和外殼的左側(當面向繼電器前部時)。箱子標簽詳細說明了可以安裝的裝置。箱子標簽詳細說明了以下信息:?型號?制造日期?特別注意事項
nuous total real power consumption Range: 0 to 999999.999 MW·hours. Timing Accuracy: ±0.5% Update Rate: 5 seconds METERED REACTIVE POWER CONSUMPTION Description: Continuous total reactive power consumption Range: 0 to 999999.999 Mvar·hours Timing Accuracy: ±0.5% Update Rate: 5 seconds METERED REACTIVE POWER GENERATION Description: Continuous total reactive power generation Range: 0 to 2000000.000 Mvar·hours Timing Accuracy: ±0.5% Update Rate: 5 seconds DEMAND Metered Values: Maximum Phase Current 3 Phase Real Power 3 Phase Apparent Power 3 Phase Reactive Power Measurement Type: Rolling Demand Demand Interval: 5 to 90 minutes in steps of 1 Update Rate: 1 minute Elements: Alarm OTHER FEATURES Pre-Trip Data Event Recorder Trace Memory Starter Failure Fault Simulation VT Failure ENVIRONMENT Ambient Operating Temperature: –40°C to +60°C Ambient Storage Temperature: –40°C to +80°C Humidity: Up to 90%, non-condensing. Altitude: Up to 2000 m Pollution Degree: 2 At temperatures lower than –20°C, the LCD contrast may be impaired. It is recommended that the 469 be powered up at least once per year to prevent deterioration of electrolytic capacitors in the power supply. BATTERY BACKUP Usage: only when there is no control power to relay Life expectancy: ≥ 10 years with no control power to relay CASE Type: Fully drawout (automatic CT shorts) Seal: Seal provision Door: Dust tight door Mounting: Panel or 19" rack mount IP Class: IP20-X PRODUCTION TESTS Thermal Cycling: Operational test at ambient, reducing to –40°C and then increasing to 60°C Dielectric Strength: 2.0 kV for 1 minute from relays, CTs, VTs, power supply to Safety Ground DO NOT CONNECT FILTER GROUND TO SAFETY GROUND DURING ANY PRODUCTION TESTS! 3 3 3 3 3 3 NOTE NOTE WARNING 1-8 469 Motor Management Relay GE Multilin 1.2 SPECIFICATIONS 1 INTRODUCTION 1 TYPE TESTS Dielectric Strength: Per IEC 255-5 and ANSI/IEEE C37.90 2.0 kV for 1 minute from relays, CTs, VTs, power supply to Safety Ground Insulation Resistance: IEC255-5 500 V DC, from relays, CTs, VTs, power supply to Safety Ground DO NOT CONNECT FILTER GROUND TO SAFETY GROUND DURING DIELECTRIC STRENGTH OR INSULATION RESISTANCE TESTS! Transients: ANSI C37.90.1 Oscillatory (2.5kV/ 1MHz); ANSI C37.90.1 Fast Rise (5kV/10ns); Ontario Hydro A-28M-82; IEC255-4 Impulse/High Frequency Disturbance, Class III Level Impulse Test: IEC 255-5 0.5 Joule 5 kV RFI: 50 MHz/15 W Transmitter EMI: C37.90.2 Electromagnetic Interference at 150 MHz and 450 MHz, 10 V/m S locked position until the electrical connections are completely mated. Any 469 can be installed in any 469 case, except for custom manufactured units that are clearly identified as such on both case and unit, and are equipped with an index pin keying mechanism to prevent incorrect pairings. No special ventilation requirements need to be observed during the installation of the unit. The 469 can be cleaned with a damp cloth. Figure 2–1: DIMENSIONS To prevent unauthorized removal of the drawout unit, a wire lead seal can be installed in the slot provided on the handle. With this seal in place, the drawout unit cannot be removed. A passcode or setpoint access jumper can be used to prevent entry of setpoints but allow monitoring of actual values. If access to the front panel controls must be restricted, a separate seal can be installed on the cover to prevent it from being opened. Hazard may result if the product is not used for its intended purpose. Figure 2–2: SEAL ON DRAWOUT UNIT WARNING 2-2 469 Motor Management Relay GE Multilin 2.1 MECHANICAL 2 INSTALLATION 2 2.1.2 PRODUCT IDENTIFICATION Each 469 unit and case are equipped with a permanent label. This label is installed on the left side (when facing the front of the relay) of both unit and case. The case label details which units can be installed. The case label details the following information: ? MODEL NUMBER ? MANUFACTURE DATE ? SPECIAL NOTES The