..6-4 469電機(jī)管理繼電器GE Power Management 6.2支持的MODBUS功能6通信6 6.2支持的MODBUS功能6.2.1概述469支持以下功能:?01-讀取繼電器線圈?02-讀取數(shù)字輸入狀態(tài)?03-讀取設(shè)定值和實(shí)際值?04-讀取設(shè)定點(diǎn)和實(shí)際值·05-執(zhí)行操作?06-存儲(chǔ)單個(gè)設(shè)定值?07-讀取設(shè)備狀態(tài)?08-環(huán)回測(cè)試?16-存儲(chǔ)多個(gè)設(shè)定值6.2.2功能代碼01/02:讀取繼電器線圈/數(shù)字輸入狀態(tài)Modbus實(shí)施:讀取線圈和輸入狀態(tài)469實(shí)施:讀取繼電器盤管和數(shù)字輸入狀態(tài)對(duì)于Modbus的469實(shí)施,這些命令可用于讀取繼電器線圈狀態(tài)或數(shù)字輸入狀態(tài)。a) 功能01標(biāo)準(zhǔn)實(shí)現(xiàn)需要以下內(nèi)容:從屬地址(一個(gè)字節(jié))、功能代碼(一字節(jié))、啟動(dòng)繼電器線圈(兩字節(jié))、要讀取的線圈數(shù)(兩個(gè)字節(jié))和CRC(兩個(gè))。從機(jī)響應(yīng)包括從機(jī)地址(一個(gè)字節(jié))、功能代碼(一個(gè))、繼電器線圈掩碼字節(jié)計(jì)數(shù)(一字節(jié);由于只有六個(gè)繼電器線圈,所以始終為01)、指示請(qǐng)求的繼電器線圈狀態(tài)的位掩碼(一個(gè)字節(jié))和CRC(兩個(gè)字節(jié))。b) FUNCTION 02標(biāo)準(zhǔn)實(shí)現(xiàn)要求如下:從屬地址(一個(gè)字節(jié))、功能代碼(一個(gè)字符)、起始數(shù)字輸入(兩個(gè)字符),要讀取的數(shù)字輸入數(shù)量(兩個(gè)字節(jié))和CRC(兩個(gè)字母)。從屬響應(yīng)是從屬地址(一個(gè)字節(jié))、功能代碼(一個(gè))、數(shù)字輸入掩碼的字節(jié)計(jì)數(shù)(一個(gè)字符)、指示所請(qǐng)求數(shù)字輸入狀態(tài)的位掩碼(一個(gè)或兩個(gè)字符)和CRC(兩個(gè)字符。注意:CRC以兩字節(jié)數(shù)字的形式發(fā)送,先發(fā)送低位字節(jié)。GE Power Management 469電機(jī)管理繼電器6-5 6通信6.2支持的MODBUS功能6 c)消息格式和示例,功能01請(qǐng)求從機(jī)11響應(yīng)繼電器線圈3至5的狀態(tài):如果輸入了零的啟動(dòng)繼電器線圈(啟動(dòng)數(shù)字輸入),則469將默認(rèn)為一。如果請(qǐng)求的繼電器數(shù)量(數(shù)字輸入數(shù)量)超過可用繼電器數(shù)量,則會(huì)提示用戶“非法數(shù)據(jù)”信息。繼電器狀態(tài)R1通電R2斷電R3斷電R4斷電R5通電R6通電位掩碼0011 0001(0 x 31)主傳輸:BYTES示例/描述從屬11功能代碼1 01的從屬地址1 0B消息讀取繼電器線圈狀態(tài)啟動(dòng)繼電器線圈2 00 03啟動(dòng)繼電器線圈3繼電器數(shù)量2 00 03 3個(gè)繼電器線圈(即R3、R4、R5)CRC 2 8C A1 CRC,通過從機(jī)11功能代碼1 01讀取繼電器線圈狀態(tài)字節(jié)計(jì)數(shù)1 01 1字節(jié)位掩碼位掩碼1請(qǐng)求繼電器的10位掩碼(0001 0000)CRC 2 53 93由從機(jī)計(jì)算的CRC注釋6-6 469電機(jī)管理繼電器GE Power Management 6.2支持的MODBUS功能6通信6 d)消息格式和示例,功能02示例1:請(qǐng)求從設(shè)備11響應(yīng)數(shù)字輸入5至9的狀態(tài):數(shù)字輸入狀態(tài)D1:訪問關(guān)閉D2:測(cè)試打開D3:?jiǎn)?dòng)器狀態(tài)打開D4:緊急重啟打開D5:遠(yuǎn)程重置關(guān)閉D6:可分配輸入1關(guān)閉D7:可指配輸入2關(guān)閉D8:可指派輸入3關(guān)閉D9:可指定輸入4關(guān)閉位掩碼(LSB)0111 0001位掩碼(MSB)0000 0001
6-4 469 Motor Management Relay GE Power Management 6.2 SUPPORTED MODBUS FUNCTIONS 6 COMMUNICATIONS 6 6.2 SUPPORTED MODBUS FUNCTIONS 6.2.1 OVERVIEW The following functions are supported by the 469: ? 01 - Read Relay Coil ? 02 - Read Digital Input Status ? 03 - Read Setpoints and Actual Values ? 04 - Read Setpoints and Actual Values ? 05 - Execute Operation ? 06 - Store Single Setpoint ? 07 - Read Device Status ? 08 - Loopback Test ? 16 - Store Multiple Setpoints 6.2.2 FUNCTION CODES 01/02: READ RELAY COIL / DIGITAL INPUT STATUS Modbus implementation: Read Coil and Input Status 469 Implementation: Read Relay Coil and Digital Input Status For the 469 implementation of Modbus, these commands can be used to read Relay Coil Status or Digital Input Status. a) FUNCTION 01 The standard implementation requires the following: slave address (one byte), function code (one byte), starting relay coil (two bytes), number of coils to read (two bytes), and CRC (two bytes). The slave response is the slave address (one byte), function code (one byte), relay coil mask byte count (one byte; always 01 since only six relay coils), bit mask indicating the status of requested relay coils (one byte), and CRC (two bytes). b) FUNCTION 02 The standard implementation requires the following: slave address (one byte), function code (one byte), starting digital input (two byte), number of digital inputs to read (two bytes), and CRC (two bytes). The slave response is the slave address (one byte), function code (one byte), byte count of digital input mask (one byte), bit mask indicating the status of requested digital inputs (one or two bytes), and CRC (two bytes). Note: the CRC is sent as a two byte number with the low order byte sent first. GE Power Management 469 Motor Management Relay 6-5 6 COMMUNICATIONS 6.2 SUPPORTED MODBUS FUNCTIONS 6 c) MESSAGE FORMAT AND EXAMPLE, FUNCTION 01 Request slave 11 to respond with status of relay coil 3 to 5: If STARTING RELAY COIL (STARTING DIGITAL INPUT) of Zero is entered, then 469 will default it to One. If the NUMBER OF RELAYS (NUMBER OF DIGITAL INPUTS) requested exceeds the number of relays available then user is prompted with a “ILLEGAL DATA” message. Relay Status R1 Energized R2 De-energized R3 De-energized R4 De-energized R5 Energized R6 Energized Bit Mask 0011 0001 (0 x 31) MASTER TRANSMISSION: BYTES EXAMPLE / DESCRIPTION SLAVE ADDRESS 1 0B message for slave 11 FUNCTION CODE 1 01 read relay coil status STARTING RELAY COIL 2 00 03 starting relay coil 3 NUMBER OF RELYAS 2 00 03 3 relays coils (i.e. R3, R4, R5) CRC 2 8C A1 CRC calculated by the master SLAVE RESPONSE: BYTES EXAMPLE / DESCRIPTION SLAVE ADDRESS 1 0B response message from slave 11 FUNCTION CODE 1 01 read relay coil status BYTE COUNT 1 01 1 byte bit mask BIT MASK 1 10 bit mask of requested relay (0001 0000) CRC 2 53 93 CRC calculated by the slave NOTE 6-6 469 Motor Management Relay GE Power Management 6.2 SUPPORTED MODBUS FUNCTIONS 6 COMMUNICATIONS 6 d) MESSAGE FORMAT AND EXAMPLE, FUNCTION 02 Example 1: Request slave 11 to respond with status of digital inputs 5 to 9: Digital Input Status D1: Access Closed D2: Test Open D3: Starter Status Open D4: Emergency Restart Open D5: Remote Reset Closed D6: Assignable Input 1 Closed D7: Assignable Input 2 Closed D8: Assignable Input 3 Closed D9: Assignable Input 4 Closed Bit Mask (LSB) 0111 0001 Bit Mask (MSB) 0000 0001