A-B 2094-BM01-S B 工控機器人備件
不模擬模型控制器45MLA-CTRLALG基本模型控制器45MLA-CTRL-BSC I/O模型控制器45ML A-CTRL RS-485控制器45MLA CTRL-485 CAN控制器45MLA-CTRL-CAN環(huán)境認證c-UL-us和CE標記適用于所有適用指令操作環(huán)境?外殼:IP54?接線板:IP20工作溫度0…55°c(32…131°F)存儲溫度-25…+70°C(-13…+158°F)相對濕度15…95%光學狀態(tài)指示器對準、目標存在、輸出、輸入、電源電壓24V DC±15%(20.4…27.6V),最大(2級)紋波=5%電流消耗<300 mA,控制器的最大波束數,輸出未連接傳感器保護EN 61000-4-2、EN 61000-4-4和EN 61000-4-5;短路(SCP),和過載輸出響應時間參見第2頁上的響應時間輸出類型NPN和PNP(推挽輸出)輸出模式暗操作(當連接為PNP時)輸出電流最大150 mA每種輸入類型下沉或源(跳線可選,默認用于連接到PNP輸出)機械連接類型?彈簧加載可拆卸端子板?2 x RJ45(僅連接到燈陣列)?僅限CAN型號:用于CAN通信的兩個額外RJ45連接器材料外殼ABS(FR)UL94-V0聚碳酸酯外殼所需配件45MLA燈陣列(類別號45MLA-xxxxx 0Pxx)。請參見第11頁的附件。注意:這些設備僅用于物體識別,不得用于保護人身(進入保護)。警察的唯一目的是偵察目標,并利用人類保護(保護行動)最高環(huán)境溫度:55°C(131°F)環(huán)境溫度最高:55°F(131°C)注意:必須使用提供的索環(huán)安裝電纜,以保持IP54標準。不允許允許電纜在安裝環(huán)境中受到擠壓或機械應力。
Not simulating model controller 45MLA-CTRLALG basic model controller 45MLA-CTRL-BSC I/O model controller 45MLA-CTRL RS-485 controller 45MLA CTRL-485 CAN controller 45MLA-CTRL-CAN environmental certification c-UL us and CE mark are applicable to all applicable command operating environments ? Housing: IP54 ? Terminal block: IP20 operating temperature 0... 55 ° c (32... 131 ° F) Storage temperature - 25...+70 ° C (- 13...+158 ° F) Relative humidity 15... 95% Optical status indicator alignment Target presence, output, input, power supply voltage 24V DC ± 15% (20.4... 27.6V), maximum (level 2) ripple=5%, current consumption<300 mA, maximum number of beams of the controller, output sensor protection without connection EN 61000-4-2, EN 61000-4-4 and EN 61000-4-5; Short circuit (SCP), And overload output response time See response time on page 2 Output types NPN and PNP (push-pull output) Output mode Dark operation (when connected to PNP) Output current max. 150 mA Sink or source of each input type (jumper optional, default for connecting to PNP output) Mechanical connection type ? Spring loaded removable terminal board ? 2 x RJ45 (only connected to lamp array) ? Only for CAN models: two additional RJ45 connector material shells for CAN communication ABS (FR) UL94-V0 polycarbonate shell accessories 45MLA lamp array (category number 45MLA-xxxxx 0Pxx). Please refer to the attachment on page 11. Note: These devices are only used for object identification and should not be used for personal protection (entry protection). The sole purpose of the police is to detect the target and use human protection (protection operation). The maximum ambient temperature is 55 ° C (131 ° F). The maximum ambient temperature is 55 ° F (131 ° C). Note: the cable must be installed with the grommet provided to maintain the IP54 standard. The cable shall not be allowed to be subjected to extrusion or mechanical stress in the installation environment.