Woodward 9907-1200備件模塊
安裝注意事項
在安裝計算機之前,請閱讀并遵循這些注意事項。環境和外殼信息歐盟指令此計算機在安裝時符合歐盟指令要求在歐盟或EEA地區,并具有CE標志。符合性聲明的副本可在證明為了符合要求,電纜類型應采用以下標準。注意:本設備適用于污染等級為2級的工業環境、II類過電壓應用(如IEC 60664-1中所定義)、海拔2000米(6561英尺)以下且不降額的環境。根據IEC/CISPR 22,該設備被視為第1組A類工業設備。如果沒有適當的預防措施,由于傳導干擾和輻射干擾,在其他環境中的電磁兼容性可能存在潛在困難。該設備作為開放式設備提供。為了滿足某些法規要求,計算機必須安裝在一個外殼中,該外殼針對可能存在的環境條件進行了適當設計,并進行了適當的設計,以防止因接觸帶電部件而造成人身傷害。
接地指南
必須使用工具才能接近外殼內部。所有6181X-12顯示計算機均配有墊圈擋板,僅當安裝在具有同等額定值的面板或外殼中時,才能滿足指定的NEMA、UL類型和IEC額定值。除本出版物外,請參閱以下內容:?工業自動化布線和接地指南,出版物1770-4.1,了解其他安裝要求?NEMA標準250、UL 50和IEC 60529(如適用),了解外殼提供的防護等級說明注意:符合EN 55022和EN 55024,所有I/O電纜必須小于30米(98.42英尺),并且只能在室內使用。這些電纜在任何時候都不能離開建筑物,也不能直接連接到建筑物外的電纜。所需電纜類型屬性電纜類型所需屬性LAN屏蔽或非屏蔽DP屏蔽USB屏蔽VGA屏蔽串行RS-232屏蔽直流電源非屏蔽DVI屏蔽自動化出版物安裝第2章危險場所本設備適用于這些場所類別。
Installation precautions
Read and follow these precautions before installing your computer. Environment and Enclosure Information EU Directives This computer meets the requirements of EU Directives when installed in the EU or EEA region, and has the CE mark. A copy of the declaration of conformity can be used to prove that the following standards shall be adopted for cable types in order to meet the requirements. Note: This equipment is applicable to industrial environment with pollution level of 2, overvoltage application of Class II (as defined in IEC 60664-1), and environment with altitude below 2000 meters (6561 feet) and no derating. According to IEC/CISPR 22, this equipment is considered as Group 1 Class A industrial equipment. Without proper preventive measures, electromagnetic compatibility in other environments may have potential difficulties due to conducted interference and radiated interference. The device is provided as an open device. In order to meet certain regulatory requirements, the computer must be installed in an enclosure that is properly designed for possible environmental conditions and is designed to prevent personal injury due to contact with live parts.
Grounding Guidelines
Tools must be used to access the inside of the enclosure. All 6181X-12 display computers are equipped with a gasket bezel that meets the specified NEMA, UL type, and IEC ratings only when installed in an equally rated panel or enclosure. In addition to this publication, refer to the following: ? Industrial Automation Wiring and Grounding Guidelines, Publication 1770-4.1, for additional installation requirements ? NEMA Standard 250, UL 50, and IEC 60529 (as applicable), for the degree of protection provided by enclosures Note: Comply with EN 55022 and EN 55024, all I/O cables must be less than 30 meters (98.42 feet), and can only be used indoors. These cables cannot leave the building at any time, nor can they be directly connected to the cables outside the building. Required Cable Type Properties Required Cable Type Properties LAN Shielded or Unshielded DP Shielded USB Shielded VGA Shielded Serial RS-232 Shielded DC Power Unshielded DVI Shielded Automation Publication Installation Chapter 2 Hazardous Locations This equipment is applicable to these site categories.