DS200TCQCG1BGFDCS控制模塊
注1:
取決于模塊和環(huán)境的實(shí)際通道配置。有關(guān)計(jì)算方法,請(qǐng)參閱《用戶指南》。注2:如果負(fù)載電流小于20mA,為數(shù)字輸出配置的通用IO通道可能會(huì)錯(cuò)誤報(bào)告線路監(jiān)測(cè)或“OP故障”故障。注3:短路將在2微秒內(nèi)限制為小于1.4安培,在10微秒內(nèi)將限制為750 mA。如果短時(shí)間持續(xù)超過(guò)10毫秒,DO通道將關(guān)閉注4:請(qǐng)參考《用戶指南》中的計(jì)算方法,以確定通道使用與工作溫度的關(guān)系。5.20.通用輸入輸出–CC-PUIO31功能通用輸入輸出模塊與模擬輸入、模擬輸出、數(shù)字輸入和數(shù)字輸出現(xiàn)場(chǎng)設(shè)備接口。
可配置為
值得注意的功能?每個(gè)通道用戶可配置為:?模擬輸入?模擬輸出?數(shù)字輸入?DISOE-事件序列(1ms分辨率SOE,20ms PV掃描)?數(shù)字輸出?脈沖輸入(任何四個(gè)通道)?開(kāi)路檢測(cè)?電子短路保護(hù)1?快速掃描(優(yōu)先I/O模塊掃描)?安全狀態(tài)(FAILOPT)行為數(shù)字/模擬輸出的信道基礎(chǔ)?HART 7支持(模擬輸入/輸出)?每個(gè)信道的HART調(diào)制解調(diào)器實(shí)現(xiàn)快速性能?擴(kuò)展溫度范圍-40至+70°C模塊環(huán)境模型規(guī)范參數(shù)規(guī)范通用過(guò)程IO模塊CC-PUIO31 IOTA型號(hào)CC-TUIO31非冗余9“CC-TUIO 41冗余12”注1:每個(gè)信號(hào)可以在現(xiàn)場(chǎng)短路IOM或IOTA損壞。
Note 1:
Depends on the actual channel configuration of the module and environment. For calculation methods, refer to the User Guide. Note 2: If the load current is less than 20mA, the general IO channel configured for digital output may incorrectly report line monitoring or "OP fault" fault. Note 3: Short circuit will be limited to less than 1.4 amperes in 2 microseconds and 750 mA in 10 microseconds. If the short time lasts for more than 10 milliseconds, the DO channel will be closed Note 4: Please refer to the calculation method in the User's Guide to determine the relationship between channel use and operating temperature. 5.20. Universal I/O – CC-PUIO31 function universal I/O module interfaces with analog input, analog output, digital input and digital output field devices.
Configurable as
Notable functions ? Users can configure each channel as follows: ? Analog input ? Analog output ? Digital input ? DISOE event sequence (1ms resolution SOE, 20ms PV scan) ? Digital output ? Pulse input (any four channels) ? Open circuit detection ? Electronic short circuit protection 1 ? Fast scan (priority I/O module scan) ? Safety status (FAILOPT) behavior Digital/analog output channel basis ? HART 7 support (analog input/output) ? HART modem for each channel achieves fast performance ? Extended temperature range - 40 to+70 ° C Module environment model specification parameter specification General process IO module CC-PUIO31 IOTA model CC-TUIO31 non redundant 9 "CC-TUIO 41 redundant 12" Note 1: Each signal can be short circuited in the field IOM or IOTA damaged.