330850-50-00工控模塊備件
必須符合以下兩個條件
符合性和認證FCC此設備符合FCC規(guī)則第15部分的要求。操作必須符合以下兩個條件l本設備可能不會造成有害干擾。l此設備必須接受接收到的任何干擾,包括可能導致不期望操作的干擾。EMC EMC指令2014/30/歐盟RoHS RoHS指令2011/65/僅限歐盟海事330400和330425 ABS 2009鋼制船舶規(guī)則1-1-4/7.7,4-8-3/1.11.1,4-9-7/13 330500 Velomitor壓電速度傳感器數(shù)據(jù)表3/11 141632修訂版N危險區(qū)域批準CSA/NRTL/C 190501(機構(gòu)批準選項01至04)本質(zhì)安全Ex ia IIC T4:I級,1區(qū),D組II級,E組,F(xiàn)和G III類AEx ia IIC T4:I類1區(qū)D組;II級,E、F、G組III級,根據(jù)圖紙167536 T4在-40°C下安裝≤ 助教≤ +100°C(-40°F≤ 助教≤ +212°F)本質(zhì)安全和非易燃Ex nL IIC T4 I級2區(qū)C和D組AEx nA T4 I類2區(qū)A組D組根據(jù)圖紙167536 T4在-40°C下安裝≤ 助教≤ +100°C(-40°F≤ 助教≤ +212°F)330400、330425 Ex ia IIC T4 AEx ia IIC T 4 I級,1區(qū)C和D組II級,E、F和G組III級T4@-40°C≤ 助教≤ 100°C根據(jù)圖紙167538 330500 Ex ia IIC T4 AEx ia IIC T 4 I級,1區(qū),C和D組II級,E、F、G組III級
安裝按照圖紙
167537 T4在-40°C下安裝≤ 助教≤ 100°C Ex nL IIC T4 AEx nA IIC T5 I級2區(qū)D組根據(jù)圖紙167537 T4在-40°C下安裝≤ 助教≤ 100°C 330525 Ex ia IIC T4 AEx ia IIC T 4 I級,1類,C和D組II級,E、F、G組III級T4@-40°C≤ 助教≤ 100°C Ex nL IIC T4 AEx nA IIC T5 I級2區(qū)D組根據(jù)圖紙167539 T4在-40°C下安裝≤ 助教≤ 100°C ATEX/IECEx 190501、330400、330425、330500、330525 190501實體參數(shù)II 1 G Ex ia IIC T4 Ga II 3 D Ex na IIC T5 Gc Ex tc III T130°C Dc T4@Ta=-55°C至121°C區(qū)域0/1區(qū)域2 Ui=30V Ui=30 V II=200 mA II=200mA Pi=0.75W Pi=1.14W Ci-27.2nF Li=0 330400,330425,330500,330525 II 1 G Ex ia IIC T30 Ga II D 330500 Vel omitor壓電速度傳感器數(shù)據(jù)表4/11 141632修訂版。N實體參數(shù)Ex na IIC T4 Gc Ex tc III T130°C Dc T4@Ta=-55°C至121°C 0/1區(qū)2 Ui=28V Ui=280V Ii=150mA Ii=0.84W Pi=1.26W Ci-10.8nF Li=0危險區(qū)域安全使用條件ATEX/IECEx 0/1區(qū):設備必須連接到符合上述實體參數(shù)的設備。A或B型電纜(符合EN 60079-25)必須符合實體參數(shù)中列出的電纜參數(shù)。區(qū)域2:電源電氣參數(shù)不得超過上表中提到的值。
The following two conditions must be met
Compliance and Certification FCC This equipment complies with the requirements of Part 15 of the FCC Rules. Operation must meet the following two conditions l This equipment may not cause harmful interference. L This equipment must accept any interference received, including interference that may cause undesired operation. EMC EMC Directive 2014/30/EU RoHS RoHS Directive 2011/65/EU Maritime 330400 and 330425 ABS 2009 Steel Ship Rules 1-1-4/7.7, 4-8-3/1.11.1, 4-9-7/13 330500 Velomitor Piezoelectric Speed Sensor Data Sheet 3/11 141632 Rev. N Hazardous Area Approval CSA/NRTL/C 190501 (Agency Approval Options 01 to 04) Intrinsic Safety Ex ia IIC T4: Class I, Zone 1, Group D, Class II, Group E, Class F and G III AEx ia IIC T4: Class I, Zone 1, Group D; Class II, Groups E, F, G, Class III, installed at - 40 ° C according to drawing 167536 T4 ≤ teaching assistant ≤+100 ° C (- 40 ° F ≤ teaching assistant ≤+212 ° F) Intrinsically safe and non flammable Ex nL IIC T4, Class I, Zone 2, Group C and D AEx nA T4, Class I, Zone 2, Group A, Group D, installed at - 40 ° C according to drawing 167536 T4 ≤ teaching assistant ≤+100 ° C (- 40 ° F ≤ teaching assistant ≤+212 ° F) 330400, 330425 Ex ia IIC T4 AEx ia IIC, Group T 4, Class I, Zone 1, Group C and D II Class, Groups E, F, and G Class III T4@-40 ° C ≤ TA ≤ 100 ° C As per drawing 167538 330500 Ex ia IIC T4 AEx ia IIC T4 Class I, Zone 1, Groups C and D Class II, Groups E, F, G Class III
Installation as per drawing
167537 T4 installed at - 40 ° C ≤ TA ≤ 100 ° C Ex nL IIC T4 AEx nA IIC T5 Class I, Zone 2, Group D according to drawing 167537 T4 installed at - 40 ° C ≤ TA ≤ 100 ° C 330525 Ex ia IIC T4 AEx ia IIC T4 Class I, Class 1, Groups C and D Class II, Groups E, F, G Class III T4@-40 ° C ≤ Assistant ≤ 100 ° C Ex nL IIC T4 AEx nA IIC T5 Class I, Zone 2, Group D, installed at - 40 ° C according to drawing 167539 T4 ≤ Assistant ≤ 100 ° C ATEX/IECEx 190501, 330400, 330425, 330500, 330525 190501 Entity parameters II 1 G Ex ia IIC T4 Ga II 3 D Ex na IIC T5 Gc Ex tc III T130 ° C Dc T4@Ta =-55 ° C to 121 ° C Zone 0/1 Zone 2 Ui=30V Ui=30 V II=200 mA II=200mA Pi=0.75W Pi=1.14W Ci-27.2nF Li=0 33040033042533000330525 II 1 G Ex ia IIC T30 Ga II D 330500 Vel monitor Piezoelectric Velocity Sensor Data Sheet 4/11 141632 Rev. N Entity parameter Ex na IIC T4 Gc Ex tc III T130 ° C Dc T4@Ta =-Zone 0/1 from 55 ° C to 121 ° C 2 Ui=28V Ui=280V Ii=150mA Ii=0.84W Pi=1.26W Ci-10.8nF Li=0 Conditions for safe use in hazardous areas ATEX/IECEx Zone 0/1: the equipment must be connected to the equipment meeting the above physical parameters. Type A or B cables (according to EN 60079-25) must conform to the cable parameters listed in the physical parameters. Zone 2: The electrical parameters of the power supply shall not exceed the values mentioned in the above table.