330500-02-00自動化模塊
符合性和認證FCC
此設備符合FCC規則第15部分的要求。操作必須符合以下兩個條件:l本設備可能不會造成有害干擾。l此設備必須接受接收到的任何干擾,包括可能導致不期望操作的干擾。EMC EMC指令2014/30/歐盟RoHS RoHS指令2011/65/僅限歐盟海事330400和330425 ABS 2009鋼制船舶規則1-1-4/7.7,4-8-3/1.11.1,4-7/13危險區域批準CSA/NRTL/C 190501(機構批準選項01至04)本質安全Ex ia IIC T4:I級,1區,A、B、C、D組II級,E、F和G III級AEx ia IIC T:I級、1區,B、C和D組;II級,E、F、G組III級,根據圖紙167536 T4在-40°C下安裝≤ 助教≤ +100°C(-40°F≤ 助教≤ +212°F)本質安全和非易燃Ex nL IIC T4 I級2區A、B、C和D組AEx nA T4 I類2區A組B、C、D組根據圖紙167536 T4在-40°C下安裝≤ 助教≤ +100°C(-40°F≤ 助教≤ +212°F)330400、330425 Ex ia IIC T4 AEx ia IIC T 4 I級,1區A、B、C和D組II級,E、F和G組III級T4@-40°C≤ 助教≤ 100°C根據圖紙167538 330500 Ex ia IIC T4 AEx ia IIC T 4 I級,1區,A、B、C和D組II級,E、F、G組III級安裝按照圖紙167537 T4在-40°C下安裝≤ 助教≤ 100°C Ex nL IIC T4 AEx nA IIC T5 I級2區A、B、C、D組根據圖紙167537 T4在-40°C下安裝≤ 助教≤ 100°C 330525 Ex ia IIC T4 AEx ia IIC T 4 I級,1類,A、B、C和D組II級,E、F、G組III級T4@-40°C≤ 助教≤ 100°C Ex nL IIC T4 AEx nA IIC T5 I級2區A、B、C、D組根據圖紙167539 T4在-40°C下安裝≤ 助教≤ 100°C ATEX/IECEx 330400和330425加速度傳感器數據表4/10 141638 Rev.W 190501、330400、330425、330500、330525 190501實體參數II 1 G Ex ia IIC T4 Ga II 3 D Ex na IIC T5 Gc Ex tc III T130°C Dc T4@Ta=-55°C至121°C區域0/1區域2 Ui=30V Ui=30 V II=200 mA II=200mA Pi=0.75W Pi=1.14W Ci-27.2nF Li=0 330400、430425 330500,330525實體參數II 1 G Ex ia IIC T4 Ga II 3 D Ex na IIC T6 Gc Ex tc III T130°C Dc T4@Ta=-55°C至121°C 0/1區2 Ui=28V Ui=28 V II=150 mA II=150mA Pi=0.84W Pi=1.26W Ci-10.8nF Li=0
危險區域安全使用條件
ATEX/IECEx 0/1區:設備必須連接到符合上述實體參數的設備。A或B型電纜(符合EN 60079-25)必須符合實體參數中列出的電纜參數。區域2:電源電氣參數不得超過上表中提到的值。330400和330425加速計加速度傳感器數據表5/10 141638版本W訂購信息有關國家和產品特定批準的詳細列表,請參閱Bently.com上的批準快速參考指南,文件108M1756。330400加速計330425加速計零件號AA BB A:安裝螺紋選項0 1?-28 UNF整體螺柱0 2 M8 X 1整體螺柱B:機構批準選項0 0無0 5多重批準(CSA、ATEX、IECEx)互連電纜零件號AA A:電纜長度選項(英尺)對于以下列出的電纜,訂購增量為1.0英尺(305 mm)。示例:1 5=15英尺(4.57米)2 0=20英尺(6.10米)以下為標準長度英尺米(約)6 1.8 8 2.4 10 3.0 12 3.6 15 4.5 17 5.0 20 6.0 25 7.6 30 9.0 33 10.0 50 15.2 99 30.0也可額外訂購非標準/定制長度。電纜零件號130539 3芯屏蔽18 AWG(1.0 mm2)電纜,一端帶有3插座插頭和氟硅橡膠護套,另一端帶有接線片。最小長度為2.0英尺(0.6米),最大長度為99英尺(30米)。有手冊可幫助安裝該電纜(零件號133080-01)。16925 3芯屏蔽22 AWG(0.5 mm2)電纜,一端帶3插座插頭,另一端帶接線片。最小長度為2.0英尺(0.6米),最大長度為99英尺(30米)。16710 3芯屏蔽22 AWG(0.5 mm2)鎧裝電纜,一端帶3插座插頭,另一端帶接線片。最小長度為3.0英尺(0.9米),最大長度為99英尺(30米)。附件127088-01 330400和330425加速計操作手冊。00531080用于330400和330425加速計的匹配連接器。37439-01用于序列號前不帶字母“G”的情況。安裝底座,?-28至?-28.降低底座應變敏感性。37439-02用于序列號前不帶字母“G”的情況。安裝底座,M8X1至M8X1.降低底座應變敏感性。43217加速計安裝套件,用于延伸件零件號108576-01和O形圈零件號04290422,以便為
Compliance and Certification FCC
This device complies with the requirements of Part 15 of the FCC Rules. Operation must meet the following two conditions: l This equipment may not cause harmful interference. L This equipment must accept any interference received, including interference that may cause undesired operation. EMC EMC Directive 2014/30/EU RoHS RoHS Directive 2011/65/EU Maritime 330400 and 330425 ABS 2009 Steel Ship Rules 1-1-4/7.7, 4-8-3/1.11.1, 4-7/13 Hazardous Area Approval CSA/NRTL/C 190501 (Agency Approval Options 01 to 04) Intrinsic Safety Ex ia IIC T4: Class I, Zone 1, Groups A, B, C, D Class II, E, F and G Class III AEx ia IIC T: Class I, Zone 1, Groups B, C and D; Class II, Groups E, F, G Class III, installed at - 40 ° C according to drawing 167,536 T4 ≤ teaching assistant ≤+100 ° C (- 40 ° F ≤ teaching assistant ≤+212 ° F) Intrinsically safe and non flammable Ex nL IIC T4 Class I, Division 2, Groups A, B, C, and D AEx nA T4 Class I, Division 2, Group A, Groups B, C, and D installed at - 40 ° C according to drawing 167,536 T4 ≤ teaching assistant ≤+100 ° C (- 40 ° F ≤ teaching assistant ≤+212 ° F) 330,400, 330,425 Ex ia IIC T4 AEx ia IIC T 4 Class I, Zone 1, Groups A, B, C, and D, Class II, E Groups F and G Class III T4@-40 ° C ≤ teaching assistant ≤ 100 ° C According to drawing 167538 330500 Ex ia IIC T4 AEx ia IIC T4 Class I, Zone 1, Groups A, B, C and D Class II, Groups E, F and G Class III Installation according to drawing 167537 T4 Installation at - 40 ° C ≤ teaching assistant ≤ 100 ° C Ex nL IIC T4 AEx nA IIC T5 Class I, Zone 2 Groups A, B, C and D Installation at - 40 ° C according to drawing 167537 T4 ≤ teaching assistant ≤ 100 ° C 330525 Ex ia IIC T4 AEx ia IIC T4 Class I, Class 1, Groups A, B, C, and D, Class II, E, F Group G Grade III T4@-40 ° C ≤ TA ≤ 100 ° C Ex nL IIC T4 AEx nA IIC T5 Class I, Zone 2, Groups A, B, C, D are installed at - 40 ° C according to drawing 167539 T4 ≤ TA ≤ 100 ° C ATEX/IECEx 330400 and 330425 acceleration sensor data sheet 4/10 141638 Rev. W 190501, 330400, 330425, 330500, 330525 190501 Real parameter II 1 G Ex ia IIC T4 Ga II 3 D Ex na IIC T5 Gc Ex tc III T130 ° C Dc T4@Ta =-55 ° C to 121 ° C Zone 0/1 Zone 2 Ui=30V Ui=30 V II=200 mA II=200mA Pi=0.75W Pi=1.14W Ci-27.2nF Li=0 330400, 430425 330500330525 Entity parameters II 1 G Ex ia IIC T4 Ga II 3 D Ex na IIC T6 Gc Ex tc III T130 ° C Dc T4@Ta =-55 ° C to 121 ° C Zone 0/1 2 Ui=28V Ui=28V II=150 mA II=150mA Pi=0.84W Pi=1.26W Ci-10.8nF Li=0
Conditions for safe use in hazardous areas
ATEX/IECEx Zone 0/1: The equipment must be connected to the equipment meeting the above entity parameters. Type A or B cables (according to EN 60079-25) must conform to the cable parameters listed in the physical parameters. Zone 2: The electrical parameters of the power supply shall not exceed the values mentioned in the above table. 330400 and 330425 Accelerometer Accelerometer Sensor Data Sheet 5/10 141638 Version W Ordering Information For a detailed list of country and product specific approvals, see Bently Quick Reference Guide for Approvals on. com, document 108M1756. 330400 Accelerometer 330425 Accelerometer Part Number AA BB A: Mounting Thread Option 0 1 ?- 28 UNF integral stud 0 2 M8 X 1 integral stud B: Agency approved option 0 0 None 0 5 Multiple approvals (CSA, ATEX, IECEx) Interconnect cable part number AA A: Cable length option (feet) For the cables listed below, order in increments of 1.0 feet (305 mm). Example: 1 5=15 feet (4.57 meters) 2 0=20 feet (6.10 meters) below is the standard length feet meters (approximately) 6 1.8 8 2.4 10 3.0 12 3.6 15 4.5 17 5.0 20 6.0 25 7.6 30 9.0 33 10.0 50 15.2 99 30.0 Additional non-standard/custom lengths can also be ordered. Cable part number 130539 3-core shielded 18 AWG (1.0 mm2) cable with a 3-socket plug and fluorosilicone rubber sheath at one end and a lug at the other end. The minimum length is 2.0 feet (0.6 meters) and the maximum length is 99 feet (30 meters). A manual is available to help install the cable (part number 133080-01). 16925 3-core shielded 22 AWG (0.5 mm2) cable with 3 socket plugs at one end and lug at the other end. The minimum length is 2.0 feet (0.6 meters) and the maximum length is 99 feet (30 meters). 16710 3-core shielded 22 AWG (0.5 mm2) armored cable with 3 socket plugs at one end and lug at the other end. The minimum length is 3.0 feet (0.9 meters) and the maximum length is 99 feet (30 meters). Attachment 127088-01 330400 and 330425 Accelerometer Operation Manual. 00531080 is used for matching connector of 330400 and 330425 accelerometers. 37439-01 is used when there is no letter "G" before the serial number. Mounting base, ?- 28 to ?- 28. Reduce the base strain sensitivity. 37439-02 is used when there is no letter "G" before the serial number. Mount the base, M8X1 to M8X1. Reduce the base strain sensitivity. 43217 Accelerometer mounting kit for extension part number 108576-01 and O-ring part number 04290422 to