330130-040-00-00延伸線纜
機構(gòu)批準(zhǔn)
3301機架可獲得以下機構(gòu)批準(zhǔn):無CSA-NRTL/C CE批準(zhǔn)如果CE標(biāo)志適用于機架安裝,則選擇此框。機架安裝選項選擇已安裝或即將安裝的3301機架類型。有關(guān)各種安裝選項的說明,請參閱3301監(jiān)測系統(tǒng)機架安裝和維護(hù)手冊。電源以下電源可安裝在3301機架中:插槽中的上部位置插槽中的下部位置無電源AC高壓AC低壓DC高壓無電源AC高電壓AC低壓DC高電壓3.2開關(guān)允許您控制3301機架的操作并控制對機架配置的訪問。本節(jié)列出了機架接口模塊可用的軟件和硬件開關(guān)。3.2.1軟件開關(guān)機架接口模塊支持一個軟件模塊開關(guān)-配置模式。該開關(guān)允許您暫時禁用監(jiān)視器和頻道功能。該開關(guān)可在機架配置軟件主屏幕上實用程序選項下的軟件開關(guān)屏幕上設(shè)置。3配置信息3301/20操作和維護(hù)12在按下設(shè)置按鈕之前,任何更改都不會生效。模塊開關(guān)配置模式允許配置機架的開關(guān)。要將機架設(shè)置為配置模式,請啟用()此開關(guān),并將機架接口模塊前部的按鍵開關(guān)設(shè)置為編程位置。下載機架接口模塊配置時,該開關(guān)將由機架配置軟件自動啟用和禁用。如果在配置過程中與機架的連接丟失,請使用此開關(guān)將模塊從配置模式中移除。
模塊開關(guān)號用于通信網(wǎng)關(guān)模塊
模塊開關(guān)編號開關(guān)名稱1配置模式3301/20操作和維護(hù)3配置信息13 3.2.2硬件開關(guān)機架接口模塊有三個硬件開關(guān),位于前面板上。鑰匙開關(guān)鑰匙開關(guān)用于防止未經(jīng)授權(quán)更改配置設(shè)置。當(dāng)開關(guān)處于運行位置時,3301機架無法配置。當(dāng)開關(guān)處于PROGRAM(編程)位置時,可配置3301機架,且機架繼續(xù)正常運行。通過拔下鑰匙,您可以將機架接口模塊鎖定在運行或編程位置。機架復(fù)位注意事項必須安裝RS-232/RS-422 I/O模塊或調(diào)制解調(diào)器I/O模塊,機架復(fù)位開關(guān)才能正常工作。當(dāng)按下機架復(fù)位開關(guān)時,機架中的任何監(jiān)測器將清除鎖定報警并復(fù)位定時OK通道失效指示。該開關(guān)執(zhí)行與機架接口輸入/輸出模塊上的機架復(fù)位觸點相同的功能。機架地址主機使用機架地址識別以菊花鏈鏈接的3301機架。使用提供63個可能地址的6位DIP開關(guān)設(shè)置機架地址。菊花鏈中的所有機架必須具有唯一的機架地址。下圖和表格顯示了如何選擇地址110001(49十進(jìn)制)。
Agency Approval
The 3301 rack can be approved by the following authorities: No CSA NRTL/C CE approval Check this box if the CE mark is applicable for rack installation. Rack Mount Options Select the 3301 rack type that is installed or will be installed. For a description of the various installation options, refer to the 3301 Monitoring System Rack Installation and Maintenance Manual. Power The following power supplies can be installed in a 3301 rack: upper position in the slot lower position in the slot no power AC high voltage AC low voltage DC high voltage no power AC high voltage AC low voltage DC high voltage 3.2 switch allows you to control the operation of the 3301 rack and control access to the rack configuration. This section lists the software and hardware switches available for the Rack Interface Module. 3.2.1 The software switch rack interface module supports a software module switch configuration mode. This switch allows you to temporarily disable the monitor and channel functions. The switch can be set on the Software Switches screen under the Utilities option on the main screen of the Rack Configuration Software. 3 Configuration Information 3301/20 Operation and Maintenance 12 No changes will take effect until the Set button is pressed. The module switch configuration mode allows you to configure the switches for the rack. To set the rack to configuration mode, enable () this switch and set the key switch on the front of the Rack Interface Module to the programmed position. When downloading the Rack Interface Module configuration, this switch is automatically enabled and disabled by the Rack Configuration Software. If the connection to the rack is lost during configuration, use this switch to remove the module from configuration mode.
The module switch number is used for the communication gateway module
Module Switch Number Switch Name 1 Configuration Mode 3301/20 Operation and Maintenance 3 Configuration Information 13 3.2.2 Hardware Switches The Rack Interface Module has three hardware switches located on the front panel. Keyswitch Keyswitch is used to prevent unauthorized changes to configuration settings. The 3301 rack cannot be configured when the switch is in the RUN position. When the switch is in the PROGRAM position, the 3301 rack can be configured and the rack continues to operate normally. You can lock the Rack Interface Module in the RUN or PROGRAM position by removing the key. Precautions for rack reset: RS-232/RS-422 I/O module or modem I/O module must be installed for the rack reset switch to work normally. When the Rack Reset switch is pressed, any monitor in the rack will clear the lockout alarm and reset the Timed OK Channel Failure indication. This switch performs the same function as the Rack Reset contact on the Rack Interface I/O Module. Rack Address The host uses the rack address to identify the 3301 rack linked in a daisy chain. Set the rack address using the 6-bit DIP switch that provides 63 possible addresses. All racks in the daisy chain must have a unique rack address. The following figure and table show how to select the address 110001 (49 decimal).