330103-00-03-10-02-05震動模塊控制器
當(dāng)配置為跳閘倍增時
雙擲(SPDT)觸點額定值最小開關(guān)電流12Vdc/100mA DC規(guī)格(電阻負(fù)載)最大開關(guān)電流5A最大開關(guān)功率70W@24 Vdc 10W@48 Vdc 9W@60 Vdc最大開關(guān)電壓60Vdc AC規(guī)格(電阻負(fù)荷)最大開關(guān)電壓5A最大開關(guān)功率150VA最大開關(guān)電壓30Vac參考危險區(qū)域?qū)S糜糜谖kU區(qū)域應(yīng)用的繼電器規(guī)格注意事項章節(jié)。觸點壽命100000次循環(huán)@5 A,250 Vac 200000次循環(huán)@1 A,24 Vdc密封環(huán)氧絕緣電阻1000 M? 最小值@500 Vdc抑制、復(fù)位和跳閘倍增輸入抑制/跳閘倍增用戶可以使用軟件將抑制/跳閘倍增輸入配置為抑制或跳閘倍增。當(dāng)配置為跳閘倍增時,將抑制/跳閘倍增觸點短路至RTN將增加報警和危險設(shè)置點。當(dāng)配置為禁止時,禁止輸入將禁止(旁路或停用)報警和危險狀態(tài)。將禁止觸點短路至禁止RTN將:l將所有可變危險狀態(tài)設(shè)置為邏輯0 l將所有變量報警狀態(tài)設(shè)置為0 l將旁路和禁止?fàn)顟B(tài)設(shè)置為1邏輯監(jiān)視器報警禁止開關(guān),和Modbus網(wǎng)關(guān)中映射的監(jiān)視器跳閘倍增開關(guān)將分別遠(yuǎn)程禁用報警和危險狀態(tài)或激活跳閘倍增。電氣激活抑制50 k? 或更少(短路)禁用禁用500 k? 或更大(打開)重置使用重置輸入重置所有鎖定報警和鎖定繼電器。如果驅(qū)動狀態(tài)的條件不再存在,將RESET觸點短路至RESET RTN將:l重置所有鎖定的報警狀態(tài)l重置所有鎖存的危險狀態(tài)l重置全部鎖存的非正常狀態(tài)l重置鎖存的繼電器將非零值寫入Modbus寄存器重置Modbus網(wǎng)關(guān)中映射的鎖存狀態(tài)將遠(yuǎn)程重置監(jiān)視器。電氣激活復(fù)位50 k? 或更少(縮短)停用重置500 k? 或更高(開路)傳感器電源1900/65A通用設(shè)備監(jiān)測器數(shù)據(jù)表8/22 173401 Rev.T所有輸出都有短路保護(hù)。
雙線電流模式
電流源3.3 mA±5%開路電壓21至24 Vdc三線電壓模式電源電壓-24.02 Vdc至-23.47 Vdc最大額定電流15 mA短路電流15.1 mA至23.6 mA 4-20 mA輸出接口數(shù)量四個輸出,其中任何一個可配置為從任何通道和任何變量提供數(shù)據(jù)。比例值4至20 mA值與通道滿標(biāo)度成比例。回路電源電壓18至36 Vdc回路電阻600? 在工作溫度范圍內(nèi)最大精度2%更新率100 mS分辨率10 mA箝位電流2 mA±10%(可配置為不正常和旁路)緩沖輸出顯示模塊顯示模塊上的單個緩沖輸出提供對輸入通道1至4的訪問。信號沒有增益,該輸出被緩沖以提供短路和EMI保護(hù)。輸出阻抗550? 最小帶寬40 kHz(顯示器模塊直接連接至顯示器)最小8 kHz(75 m(250 ft.)電纜)監(jiān)視器模塊通道1至4的每個輸入都有一個專用的緩沖輸出。信號沒有增益,也沒有縮放。每個輸出都有緩沖,以提供短路和EMI保護(hù)。輸出阻抗550? 最小帶寬40 kHz指示燈監(jiān)視器模塊狀態(tài)LED指示監(jiān)視器正常工作。顯示模塊正常LED指示監(jiān)視器何時正常工作。警報LED指示警報狀態(tài)。危險LED指示危險狀態(tài)。旁路LED指示監(jiān)視器處于旁路模式。跳閘倍增LED指示監(jiān)視器處于跳閘倍增模式。通道LED指示通道處于活動狀態(tài)。帶背光的液晶顯示器(LCD)尺寸68.6 mm(2.7英寸)寬x 35.6 mm(1.4英寸)高功率要求輸入電壓范圍18至36 Vdc工作電流0.35 A典型值,1.0 A最大工作功率8.5 W典型值,14 W最大值
When configured as Trip Multiply
Double throw (SPDT) contact rating Minimum switching current 12Vdc/100mA DC specification (resistive load) Maximum switching current 5A Maximum switching power 70W@24 Vdc 10W@48 Vdc 9W@60 Vdc maximum switching voltage 60Vdc AC specification (resistance load) maximum switching voltage 5A maximum switching power 150VA maximum switching voltage 30Vac refer to the chapter on relay specifications for hazardous area applications. Contact life 100000 cycles @ 5 A, 250 Vac 200000 cycles @ 1 A, 24 Vdc sealed epoxy insulation resistance 1000 M ? minimum value @ 500 Vdc inhibit, reset and trip multiplication input inhibit/trip multiplication user can use software to configure inhibit/trip multiplication input as inhibit or trip multiplication. When configured as Trip Multiply, short circuiting the inhibit/trip multiplier contacts to the RTN will increase alarm and danger setpoints. When configured to inhibit, the inhibit input will inhibit (bypass or disable) alarm and danger states. Short circuit the inhibit contact to the inhibit RTN Set: l all variable hazardous states to logic 0 l all variable alarm states to 0 l bypass and inhibit states to 1 logic monitor alarm inhibit switch, and monitor trip multiply switch mapped in Modbus gateway will distinguish between remote disable alarm and hazardous states or activate trip multiply. Electrical activation inhibits 50 k ? or less (short circuit) disables disabling 500 k ? or more (open) resets all lockout alarms and lockout relays using the reset input. If the conditions of the drive state no longer exist, short circuiting the RESET contact to the RESET RTN will: l Reset all locked alarm states l Reset all latched dangerous states l Reset all latched abnormal states l Reset latched relays Write non-zero values to the Modbus registers Reset latched states mapped in the Modbus gateway Reset the monitor remotely. Electrical Activation Reset 50 k ? or less (shortened) Deactivation Reset 500 k ? or more (open circuit) Sensor Power Supply 1900/65A Universal Unit Monitor Data Sheet 8/22 173401 Rev. T All outputs are short-circuit protected.
Two wire current mode
Current source 3.3 mA ± 5% Open circuit voltage 21 to 24 Vdc Three wire voltage mode Power supply voltage - 24.02 Vdc to -23.47 Vdc Maximum rated current 15 mA Short circuit current 15.1 mA to 23.6 mA 4-20 mA Output interface quantity Four outputs, any of which can be configured to provide data from any channel and any variable. The proportional value 4 to 20 mA is proportional to the full scale of the channel. Loop power voltage 18 to 36 Vdc Loop resistance 600 ? Maximum accuracy 2% Update rate 100 mS resolution 10 mA Clamping current 2 mA ± 10% (configurable as abnormal and bypass) Buffered output display module Single buffered output on the display module provides access to input channels 1 to 4. The signal has no gain and the output is buffered to provide short circuit and EMI protection. Output impedance 550 ? Minimum bandwidth 40 kHz (display module directly connected to the display) Minimum 8 kHz (75 m (250 ft.) cable) Each input to channel 1 through 4 of the monitor module has a dedicated buffered output. The signal has no gain or scaling. Each output is buffered to provide short circuit and EMI protection. Output impedance 550 ? minimum bandwidth 40 kHz indicator monitor module status LED indicates that the monitor is working properly. The display module OK LED indicates when the monitor is working properly. The alarm LED indicates the alarm status. The danger LED indicates the danger status. The bypass LED indicates that the monitor is in bypass mode. Trip Multiply LED indicates that the monitor is in Trip Multiply mode. The channel LED indicates that the channel is active. LCD with backlight Size 68.6 mm (2.7 inches) Width x 35.6 mm (1.4 inches) High power requirements Input voltage range 18 to 36 Vdc Operating current 0.35 A typical, 1.0 A maximum operating power 8.5 W typical, 14 W maximum