330001-01震動模塊控制器
精度振動變量
RMS包絡(luò)峰值為20至500 m/s2(2至50 g),RMS積分峰值為10至100 mm/s(0.4至4 in/s),均方根偏置電壓為24 V,精度振動變量為滿量程輸入阻抗的±1%,3線電壓模式為10 k? 速度和往復(fù)速度通道類型速度通道類型和往復(fù)流速通道類型支持雙線和三線壓電速度傳感器。速度變量和往復(fù)速度變量速度變量和往返速度變量是從原始傳感器信號中過濾和處理的測量值。速度通道類型和往復(fù)速度通道類型支持每個通道最多四個連續(xù)計算的變量。振動最多三次帶通濾波振幅測量。偏置電壓用戶可以將傳感器偏置電壓的值分配給任何變量??膳渲眠x項每個變量都獨立配置有以下選項。振動變量l峰值或RMS l公制或英制單位l濾波器轉(zhuǎn)角頻率l滿量程l速度集成到位移濾波器振動變量0.5 Hz至5.5 kHz,可配置8極高通,4極低通偏置濾波器0.09 Hz 1極低通OK濾波器:2.4 kHz 1極高通滿量程振動10至50 mm/s(0.5至2 in/s)峰值和RMS積分100至500μm(5至20 mil)峰間偏置電壓-24 V精度振動變量滿量程輸入阻抗的±1%3線電壓模式10 k? 徑向振動通道類型徑向振動通道使用接近傳感器測量徑向軸運動。徑向振動變量徑向振動變量是從原始傳感器中過濾和處理的測量值。徑向振動通道類型支持每個通道最多四個連續(xù)計算變量。直接最多三個帶通濾波振幅測量間隙間隙電壓振動最多三個經(jīng)帶通濾波的振幅測量可配置選項1900/65A通用設(shè)備監(jiān)測器數(shù)據(jù)表4/22 173401修訂版T每個變量可獨立配置以下選項。
振動變量
公制或英制單位l濾波器角頻率l濾波器極點數(shù)l滿量程濾波器直接濾波器1 4至4000 Hz(240至240000 RPM)直接濾波器2 1至600 Hz(60至36000 RPM)直通濾波器特性由攻擊和衰減設(shè)置的高通,1極低通間隙濾波器0.09 Hz 1極低通過振動變量0.5 Hz至4 kHz,可配置1-、2-、,或4極高通和低通,可配置OK濾波器2.4 kHz 1極低通滿量程通頻100至500μm(3至20 mil)峰間間隙-24 V精度振動變量滿量程輸入阻抗的±1%不可配置10 k? 推力通道類型推力通道類型使用接近傳感器測量軸向軸運動。推力變量推力變量是從原始傳感器信號中過濾和處理的測量值。位置軸的軸向位置間隙、電壓或位置可配置選項每個變量獨立配置有以下選項。位置變量公制或英制單位滿量程濾波器直接濾波器:1.2 Hz單極低通間隙濾波器0.41 Hz單極正常低通濾波器:2.4 kHz單極通低通滿量程位置1至4 mm(50至150 mil)量程,帶可調(diào)零位間隙-24 V準(zhǔn)確度位置變量滿量程輸入阻抗的±1%不可配置10 k? 位置通道類型位置通道類型使用接近傳感器測量機械運動。位置變量位置變量是從原始傳感器信號中過濾和處理的測量值。位置機械位置間隙、電壓或位置可配置選項
Precision vibration variable
The RMS envelope peak value is 20 to 500 m/s2 (2 to 50 g), the RMS integration peak value is 10 to 100 mm/s (0.4 to 4 in/s), the RMS root mean square bias voltage is 24 V, the precision vibration variable is ± 1% of the full range input impedance, and the 3-wire voltage mode is 10 k ? speed and reciprocating speed channel types. The speed channel type and reciprocating speed channel type support two-wire and three wire piezoelectric speed sensors. Speed variable and reciprocating speed variable Speed variable and reciprocating speed variable are the measured values filtered and processed from the original sensor signal. The Velocity Channel Type and Reciprocating Velocity Channel Type support up to four continuously calculated variables per channel. Vibration up to three band-pass filtered amplitude measurements. Offset Voltage The user can assign the value of the sensor offset voltage to any variable. Configurable Options Each variable is independently configured with the following options. Vibration variable l peak value or RMS l metric or imperial unit l filter corner frequency l full scale l speed integrated to displacement filter Vibration variable 0.5 Hz to 5.5 kHz, 8-pole high pass, 4-pole low-pass offset filter 0.09 Hz 1 pole low-pass OK filter: 2.4 kHz 1 pole high pass full scale vibration 10 to 50 mm/s (0.5 to 2 in/s) peak value and RMS integral 100 to 500 μ M (5 to 20 mil) peak to peak bias voltage - 24 V Accuracy vibration variable ± 1% of full scale input impedance% 3 Line voltage mode 10 k ? Radial vibration channel type Radial vibration channel uses proximity sensors to measure radial shaft motion. Radial vibration variable Radial vibration variable is the measured value filtered and processed from the original sensor. The radial vibration channel type supports up to four consecutive calculated variables per channel. Directly up to three band-pass filtered amplitude measurements Gap voltage vibrations Up to three band-pass filtered amplitude measurements Configurable options 1900/65A Universal Unit Monitor Data Sheet 4/22 173401 Revision T Each variable can be independently configured with the following options.
Vibration variable
Metric or imperial units l filter angular frequency l filter poles l full scale filter direct filter 1 4 to 4000 Hz (240 to 240000 RPM) direct filter 2 1 to 600 Hz (60 to 36000 RPM) pass through filter features high pass set by attack and attenuation, 1 extremely low pass gap filter 0.09 Hz 1 extremely low pass through vibration variable 0.5 Hz to 4 kHz, 1 -, 2 -, or 4-pole high pass and low pass can be configured, Configurable OK filter 2.4 kHz 1 very low pass full scale direct frequency 100 to 500 μ M (3 to 20 mil) peak to peak clearance - ± 1% of full scale input impedance of 24 V precision vibration variable is not configurable 10 k ? thrust channel type thrust channel type uses proximity sensors to measure axial shaft motion. Thrust variable The thrust variable is the measured value filtered and processed from the original sensor signal. The axial position clearance, voltage or position configurable options of the position axis are independently configured with the following options for each variable. Position variable metric or imperial unit full scale filter Direct filter: 1.2 Hz unipolar low-pass gap filter 0.41 Hz unipolar normal low-pass filter: 2.4 kHz unipolar low-pass full scale position 1 to 4 mm (50 to 150 mil) range, with adjustable zero position gap - 24 V accuracy Position variable ± 1% of full scale input impedance Not configurable 10 k ? position channel type Position channel type Use proximity sensors to measure mechanical motion. Position variable A position variable is a measured value filtered and processed from the original sensor signal. PositionMechanical PositionGap, Voltage, or PositionConfigurable Options