1900/65A-01-01-03-00-00風機振動監測器
1900/65A通用設備監測器數據表
本特利內華達州機械狀態監測說明1900/65A通用設備監測儀旨在持續監測和保護各種應用和行業中使用的設備。監測器的低成本使其成為通用機器和過程的理想解決方案,可從連續監測和保護中受益。輸入1900/65A提供四個傳感器輸入和四個溫度輸入。軟件可以配置每個傳感器輸入以支持2線和3線加速度計、速度傳感器或接近傳感器。每個溫度輸入支持E、J、K和T型熱電偶以及2線或3線RTD。輸出1900/65A提供六個繼電器輸出、四個4-20 mA記錄器輸出和一個專用緩沖輸出。
用戶使用
1900配置軟件根據任何通道或通道組合的OK、Alert和Danger狀態配置繼電器觸點打開或關閉,并在任何記錄器輸出上提供來自任何通道的任何變量的數據。專用緩沖器輸出可以為每個換能器輸入提供信號。Modbus網關選項允許監視器直接向任何Modbus客戶端提供靜態變量、狀態、事件列表、時間和日期信息,包括分布式控制系統(DCS)、監控和數據采集(SCADA)系統、可編程邏輯控制器(PLC)或System 1軟件。監視器使用內部計數器和Modbus客戶端/主時間參考來生成時間和日期信息。用戶可以通過訂購1900/01通信升級(參見訂購信息部分)來升級沒有Modbus網關的監視器。1900/65A文件:173401 Rev.T 1
Data sheet of 1900/65A general equipment monitor
Bentley Nevada Machinery Condition Monitoring Instructions The 1900/65A Universal Equipment Monitor is designed to continuously monitor and protect equipment used in a variety of applications and industries. The low cost of the monitor makes it an ideal solution for general-purpose machines and processes that benefit from continuous monitoring and protection. Input 1900/65A provides four sensor inputs and four temperature inputs. The software can configure each sensor input to support 2-wire and 3-wire accelerometers, speed sensors, or proximity sensors. Each temperature input supports E, J, K and T type thermocouples and 2-wire or 3-wire RTDs. Outputs 1900/65A provide six relay outputs, four 4-20 mA recorder outputs, and a dedicated buffered output.
User use
The 1900 configuration software configures relay contacts to open or close based on the OK, Alert, and Danger states of any channel or channel combination, and provides data on any recorder output for any variable from any channel. A dedicated buffer output can provide a signal for each transducer input. The Modbus Gateway option allows the monitor to provide static variables, status, event lists, time and date information directly to any Modbus client, including Distributed Control System (DCS), Monitoring and Data Acquisition (SCADA), Programmable Logic Controller (PLC), or System 1 software. The monitor uses internal counters and Modbus client/master time references to generate time and date information. The user can upgrade the monitor without Modbus gateway by ordering the 1900/01 communication upgrade (see the ordering information section). 1900/65A Document: 173401 Rev. T 1