產(chǎn)品內(nèi)容介紹
43AP-FA42C氣動控制器
車站通信概述每個IED都配有一個通信接口,使其能夠通過變電站自動化(SA)總線或變電站監(jiān)控(SM)總線連接到一個或多個變電站級系統(tǒng)或設(shè)備。以下通信協(xié)議可用:?IEC 61850-8-1通信協(xié)議?LON通信協(xié)議?SPA或IEC 60870-5-103通信協(xié)議?DNP3.0通信協(xié)議理論上,多個協(xié)議可以組合在同一IED中。IEC 61850-8-1通信協(xié)議IED配有用于IEC 61850-9-1站總線通信的單或雙光纖以太網(wǎng)后端口(取決于順序)。IEC 61850-8-1通信也可以從光纖以太網(wǎng)前端端口進行。IEC 61850-9-1協(xié)議允許不同供應(yīng)商的智能電氣設(shè)備(IED)交換信息并簡化系統(tǒng)工程。根據(jù)GOOSE,對等通信是該標準的一部分。提供干擾文件上傳。串行通信,LON具有ABB車站總線LON的現(xiàn)有車站可通過使用光學LON接口進行擴展。這允許完整的SA功能,包括現(xiàn)有ABB IED和新IED 670之間的點對點消息傳遞和合作。SPA通信協(xié)議為ABB SPA協(xié)議提供單個玻璃或塑料端口。這允許擴展簡單的變電站自動化系統(tǒng),但主要用于變電站監(jiān)控系統(tǒng)SMS。IEC 60870-5-103通信協(xié)議為IEC60870-5-103標準提供單個玻璃或塑料端口。這允許設(shè)計簡單的變電站自動化系統(tǒng),包括來自不同供應(yīng)商的設(shè)備。提供干擾文件上傳
DNP3.0通信協(xié)議
一個電氣RS485和一個光學以太網(wǎng)端口可用于DNP3.0通信。DNP3.0為與RTU、網(wǎng)關(guān)或HMI系統(tǒng)的通信提供了帶有主動事件、時間同步和干擾報告的2級通信。多命令和傳輸當670個IED用于帶有LON、SPA或IEC60870-5-103通信協(xié)議的變電站自動化系統(tǒng)時,事件和多命令功能塊用作與站HMI和網(wǎng)關(guān)的垂直通信接口,以及用作水平點對點通信接口(僅限LON)。IEC 62439-3并行冗余協(xié)議符合IEC 62439-1第1版和IEC 62433-3第2版的冗余站總線通信可作為670系列IED中的選項提供。IEC 62439-3并行冗余協(xié)議是可選數(shù)量,可在訂購時選擇。根據(jù)IEC 62439-3,冗余站總線通信使用OEM模塊上的端口AB和端口CD。當擴展現(xiàn)有冗余站總線DuoDriver安裝時,在訂購時選擇IEC 62439-3 Edition 1協(xié)議。訂購帶有冗余站總線的新裝置時,選擇IEC 62439-3第2版協(xié)議。IEC 62439-3第1版與IEC 62439-1第2版不兼容。模擬和二進制信號傳輸?shù)竭h程端。兩個IED之間可以交換三個模擬和八個二進制信號。此功能主要用于線路差動保護。然而,它也可以用于其他產(chǎn)品。一個IED最多可以與4個遠程IED通信。
Station communication
Overview Each IED is provided with a communication interface, enabling it to connect to one or many substation level systems or equipment, either on the Substation Automation (SA) bus or Substation Monitoring (SM) bus. Following communication protocols are available: ? IEC 61850-8-1 communication protocol ? LON communication protocol ? SPA or IEC 60870-5-103 communication protocol ? DNP3.0 communication protocol Theoretically, several protocols can be combined in the same IED. IEC 61850-8-1 communication protocol The IED is equipped with single or double optical Ethernet rear ports (order dependent) for IEC 61850-8-1 station bus communication. The IEC 61850-8-1 communication is also possible from the optical Ethernet front port. IEC 61850-8-1 protocol allows intelligent electrical devices (IEDs) from different vendors to exchange information and simplifies system engineering. Peer-to-peer communication according to GOOSE is part of the standard. Disturbance files uploading is provided. Serial communication, LON Existing stations with ABB station bus LON can be extended with use of the optical LON interface. This allows full SA functionality including peer-to-peer messaging and cooperation between existing ABB IED's and the new IED 670. SPA communication protocol A single glass or plastic port is provided for the ABB SPA protocol. This allows extensions of simple substation automation systems but the main use is for Substation Monitoring Systems SMS. IEC 60870-5-103 communication protocol A single glass or plastic port is provided for the IEC60870-5-103 standard. This allows design of simple substation automation systems including equipment from different vendors. Disturbance files uploading is provided
DNP3.0 communication protocol
An electrical RS485 and an optical Ethernet port is available for the DNP3.0 communication. DNP3.0 Level 2 communication with unsolicited events, time synchronizing and disturbance reporting is provided for communication to RTUs, Gateways or HMI systems. Multiple command and transmit When 670 IED's are used in Substation Automation systems with LON, SPA or IEC60870-5-103 communication protocols the Event and Multiple Command function blocks are used as the communication interface for vertical communication to station HMI and gateway and as interface for horizontal peerto-peer communication (over LON only). IEC 62439-3 Parallel Redundant Protocol Redundant station bus communication according to IEC 62439-3 Edition 1 and IEC 62439-3 Edition 2 are available as options in 670 series IEDs. IEC 62439-3 parallel redundant protocol is an optional quantity and the selection is made at ordering. Redundant station bus communication according to IEC 62439-3 uses both port AB and port CD on the OEM module. Select IEC 62439-3 Edition 1 protocol at the time of ordering when an existing redundant station bus DuoDriver installation is extended. Select IEC 62439-3 Edition 2 protocol at the time of ordering for new installations with redundant station bus. IEC 62439-3 Edition 1 is NOT compatible with IEC 62439-3 Edition 2.Analog and binary signal transfer to remote end Three analog and eight binary signals can be exchanged between two IEDs. This functionality is mainly used for the line differential protection. However it can be used in other products as well. An IED can communicate with up to 4 remote IEDs.
產(chǎn)品優(yōu)勢
1:國外專業(yè)的供貨渠道,具有價格優(yōu)勢
2:產(chǎn)品質(zhì)量保證,讓您售后無憂
3:全國快遞包郵
4:一對一服務(wù)
公司主營范圍簡介
PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動監(jiān)測系統(tǒng)卡件,汽輪機控制系統(tǒng)模塊,燃氣發(fā)電機備件等,優(yōu)勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進口工業(yè)零部件、歐美進口模塊。
產(chǎn)品廣泛應(yīng)用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車制造、塑膠機械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等