ACUREX 43552-010主控制板連接
ADC和Logix存儲(chǔ)器從RSLogix 5000軟件版本16.00開(kāi)始,驅(qū)動(dòng)器配置設(shè)置已存儲(chǔ)在項(xiàng)目的ACD文件中,該文件下載并存儲(chǔ)在控制器。
支持ADC的設(shè)備的配置設(shè)置包含其他端口和腳本信息來(lái)編排下載過(guò)程,因此與中的PowerFlex 750系列驅(qū)動(dòng)器相比,使用了額外的Logix內(nèi)存RSLogix 5000軟件,版本16.00…19.00系統(tǒng)。
請(qǐng)注意以下示例內(nèi)存使用:
?PowerFlex 755驅(qū)動(dòng)器,無(wú)可選模塊,參數(shù)最少更改為默認(rèn)值,并且沒(méi)有DeviceLogix程序消耗每個(gè)驅(qū)動(dòng)器大約8.5 KB的Logix內(nèi)存。
?帶有四個(gè)選項(xiàng)模塊的PowerFlex 755驅(qū)動(dòng)器,約50個(gè)更改參數(shù),32塊DeviceLogix程序消耗每個(gè)驅(qū)動(dòng)器大約有25 KB的Logix內(nèi)存。大多數(shù)Logix控制器都有兆字節(jié)的可用內(nèi)存,因此通常不應(yīng)該成為問(wèn)題。
您可以在中監(jiān)視Logix內(nèi)存使用情況RSLogix 5000軟件。在控制器屬性對(duì)話(huà)框中,單擊內(nèi)存選項(xiàng)卡。
在Logix控制器中存儲(chǔ)驅(qū)動(dòng)器和外圍設(shè)備的固件(固件管理器)Logix Firmware Supervisor(Logix固件管理器)功能已擴(kuò)展為提供固件更新連接到驅(qū)動(dòng)器的外圍設(shè)備。
您必須在線(xiàn)并加入控制器加載/存儲(chǔ)固件管理器設(shè)置的程序模式。
配置控制器以檢查和刷新驅(qū)動(dòng)器的正確固件和外圍設(shè)備,請(qǐng)執(zhí)行以下步驟。
1.驗(yàn)證是否在驅(qū)動(dòng)器和外圍設(shè)備中選擇了“完全匹配”鍵控屬性對(duì)話(huà)框。
a、 單擊常規(guī)選項(xiàng)卡以查看驅(qū)動(dòng)器的鍵控。
b、 右鍵單擊驅(qū)動(dòng)器選項(xiàng)卡上的每個(gè)外圍設(shè)備,然后選擇屬性查看外圍設(shè)備的鍵控。
2.驗(yàn)證每個(gè)固件版本的ControlFLASH固件套件應(yīng)該存儲(chǔ)在控制器中的每個(gè)設(shè)備都已安裝在運(yùn)行RSLogix 5000軟件的計(jì)算機(jī)。
3.驗(yàn)證CompactFlash或其他存儲(chǔ)卡是否已安裝在控制器。
4.使用RSLogix 5000軟件與程序中的控制器聯(lián)機(jī)模式
5.如果尚未下載程序,請(qǐng)下載。
6.在樹(shù)視圖中,右鍵單擊控制器頂部的控制器文件夾管理器,然后選擇“屬性”。
7.在控制器屬性對(duì)話(huà)框中,單擊非易失性?xún)?nèi)存選項(xiàng)卡。9.從自動(dòng)固件更新下拉菜單中,選擇啟用并將文件存儲(chǔ)到圖像。
10.單擊<--Store。
您可能會(huì)看到與以下內(nèi)容相關(guān)的兩個(gè)不同的繼續(xù)確認(rèn)對(duì)話(huà)框通信中斷和當(dāng)前內(nèi)容的擦除存儲(chǔ)卡。如果確定,請(qǐng)?jiān)谌我粚?duì)話(huà)框中單擊“是”。
11.RSLogix 5000軟件將進(jìn)入脫機(jī)狀態(tài),如下所示對(duì)話(huà)框?qū)⒊霈F(xiàn)。
ADC and Logix Memory
Starting in RSLogix 5000 software, version 16.00, drive configuration settings have been stored in the project's ACD file which is downloaded and stored in the controller. Configuration settings for ADC-capable devices contain additional port and scripting information to choreograph the download process, so additional Logix memory is used compared with PowerFlex 750-Series drives in RSLogix 5000 software, version 16.00…19.00 systems. Note these examples of memory usage: ? A PowerFlex 755 drive with no option modules, minimal parameters changed from defaults, and no DeviceLogix program consumes approximately 8.5 kilobytes of Logix memory per drive. ? A PowerFlex 755 drive with four option modules, approximately 50 changed parameters, and a 32-block DeviceLogix program consumes approximately 25 kilobytes of Logix memory per drive. The majority of Logix controllers have megabytes of memory available, so this typically should not be an issue. You can monitor Logix memory usage in RSLogix 5000 software. From the Controller Properties dialog box, click the Memory tab.
Storing the Drive’s and Peripherals’ Firmware in the Logix Controller
The Logix Firmware Supervisor function has been extended to provide firmware updates for the peripherals connected to the drive. You must be online and in program mode with the controller to load/store the firmware supervisor settings. To configure the controller to check and refresh the correct firmware for the drive and peripherals, perform the following steps. 1. Verify that “Exact Match” keying is selected in the drive’s and peripherals’ properties dialog boxes. a. Click the General tab to view the drive’s keying. b. Right-click each peripheral on the Drive tab and choose Properties to view the peripheral’s keying. 2. Verify that ControlFLASH firmware kits for each revision of firmware for each device that should be stored in the controller have been installed on the computer running RSLogix 5000 software. 3. Verify that a CompactFlash or other storage card has been installed in the controller. 4. Use RSLogix 5000 software to go online with the controller in Program mode. 5. Download your program if you have not done so already. 6. In the treeview, right-click the controller folder at the top of the Controller Organizer and choose Properties. 7. On the Controller Properties dialog box, click the Nonvolatile Memory tab.9. From the Automatic Firmware Update pull-down menu, choose Enable and Store Files to Image. 10. Click <-- Store. You may see two different continue confirmation dialog boxes relating to communication disruptions and erasure of the current contents of the storage card. If okay, click Yes on either dialog box. 11. RSLogix 5000 software will go to the Offline state, and the following dialog box will appear.
公司主營(yíng)產(chǎn)品圖展示
產(chǎn)品優(yōu)勢(shì)
1:國(guó)外專(zhuān)業(yè)的供貨渠道,具有價(jià)格優(yōu)勢(shì)
2:產(chǎn)品質(zhì)量保證,讓您售后無(wú)憂(yōu)
3:全國(guó)快遞包郵
4:一對(duì)一服務(wù)
公司主營(yíng)范圍簡(jiǎn)介
PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動(dòng)監(jiān)測(cè)系統(tǒng)卡件,汽輪機(jī)控制系統(tǒng)模塊,燃?xì)獍l(fā)電機(jī)備件等,優(yōu)勢(shì)品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進(jìn)口工業(yè)零部件、歐美進(jìn)口模塊。
產(chǎn)品廣泛應(yīng)用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機(jī)械、電子制造、汽車(chē)制造、塑膠機(jī)械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等