產(chǎn)品內(nèi)容介紹
SCHENCK 65752-01A-PWM驅(qū)動(dòng)控制器
將驅(qū)動(dòng)器/選項(xiàng)模塊添加到I/O配置
要在網(wǎng)橋和驅(qū)動(dòng)器之間傳輸數(shù)據(jù),必須將驅(qū)動(dòng)器添加為父網(wǎng)橋的子設(shè)備。
在此示例中,RSLogix 5000軟件版本20.00用于驅(qū)動(dòng)器附加配置文件版本4.03。
要確定您的驅(qū)動(dòng)器附加配置文件版本,請(qǐng)參閱Allen Bradley知識(shí)庫文檔#65882。
1.在樹視圖中,右鍵單擊網(wǎng)橋并選擇“新建模塊”以顯示選擇模塊對(duì)話框。
在我們的示例中,我們右鍵單擊1756-EN2TR/A橋。展開驅(qū)動(dòng)器組以顯示所有可用驅(qū)動(dòng)器及其通信選項(xiàng)模塊。
2.從列表中,選擇驅(qū)動(dòng)器及其連接的選項(xiàng)模塊。對(duì)于本例,我們選擇了“PowerFlex 753-ENETR”
3.單擊“確定”。在“模塊定義”對(duì)話框中,編輯以下信息。
在模塊定義對(duì)話框中,注意自動(dòng)分配的控制器標(biāo)記DriveStatus、Feedback、LogicCommand和始終使用引用。
但是,使用數(shù)據(jù)鏈接時(shí),仍必須分配主機(jī)參數(shù)01…16-[DL From Net 01-16]和主機(jī)參數(shù)17…32-[DL-ToNet 01-16]指向適當(dāng)?shù)尿?qū)動(dòng)器或連接的外圍設(shè)備盒子設(shè)置
版本驅(qū)動(dòng)器中固件(數(shù)據(jù)庫)的主要和次要版本如果駕駛是主要的并且次要版本不可用,則計(jì)算機(jī)上未安裝驅(qū)動(dòng)器數(shù)據(jù)庫。
要獲得正確的數(shù)據(jù)庫版本,請(qǐng)使用以下位于模塊定義對(duì)話框:
?創(chuàng)建數(shù)據(jù)庫:從聯(lián)機(jī)網(wǎng)絡(luò)驅(qū)動(dòng)器創(chuàng)建數(shù)據(jù)庫。單擊此按鈕顯示RSLinx軟件RSWho對(duì)話框。瀏覽到聯(lián)機(jī)驅(qū)動(dòng)器(這個(gè)例子是PowerFlex 753),選擇它,然后單擊OK。數(shù)據(jù)庫將被上傳并存儲(chǔ)在計(jì)算機(jī)上。然后,關(guān)閉模塊定義對(duì)話框并然后重新打開它以顯示新版本。
?網(wǎng)絡(luò)更新:當(dāng)驅(qū)動(dòng)器在線不可用時(shí),打開Allen Bradley驅(qū)動(dòng)器
Web更新網(wǎng)站以下載特定的數(shù)據(jù)庫文件。下載文件后,關(guān)閉“模塊定義”對(duì)話框,然后重新打開以顯示新版本。
?匹配驅(qū)動(dòng)器:當(dāng)添加到網(wǎng)絡(luò)的驅(qū)動(dòng)器匹配時(shí),使用此按鈕驅(qū)動(dòng)器配置文件(版本、額定值、數(shù)據(jù)鏈接、配置設(shè)置等)現(xiàn)有聯(lián)機(jī)網(wǎng)絡(luò)驅(qū)動(dòng)器。點(diǎn)擊此按鈕可方便地創(chuàng)建重復(fù)驅(qū)動(dòng)器配置文件,并自動(dòng)將此相同信息加載到“模塊定義”對(duì)話框。這樣就無需手動(dòng)輸入
每次將具有匹配配置文件的新驅(qū)動(dòng)器添加到網(wǎng)絡(luò)時(shí),都會(huì)顯示信息。
電子的鍵入兼容模塊。
電子鑰匙的“兼容模塊”設(shè)置驗(yàn)證物理模塊與控制器和網(wǎng)橋連接。
因此,請(qǐng)確保設(shè)置了正確的此對(duì)話框中的修訂。有關(guān)此和的其他信息,請(qǐng)參閱聯(lián)機(jī)幫助其他電子鑰匙設(shè)置。如果不需要鍵入,請(qǐng)選擇“禁用鍵入”。驅(qū)動(dòng)器不需要鍵控,因此建議使用“禁用鍵控”。
使用RSLogix 5000軟件、版本20或更高版本以及自動(dòng)設(shè)備時(shí)配置(ADC),支持固件管理器升級(jí),以存儲(chǔ)驅(qū)動(dòng)器,請(qǐng)始終選擇“完全匹配”。使用ADC時(shí),請(qǐng)參閱第70頁的表格了解更多信息細(xì)節(jié)。
Adding the Drive/Option Module to the I/O Configuration
To transmit data between the bridge and the drive, you must add the drive as a child device to the parent bridge. In this example, RSLogix 5000 software version 20.00 is used with drive Add-on Profile version 4.03. To determine your drive Add-on Profile version, see Allen-Bradley Knowledgebase document #65882. 1. In the treeview, right-click the bridge and choose New Module to display the Select Module dialog box. In our example, we right-click the 1756-EN2TR/A bridge. Expand the Drives group to display all of the available drives with their communication Option Modules.2. From the list, select the drive and its connected option module. For this example, we selected “PowerFlex 753-ENETR.” 3. Click OK.
In the Module Definition dialog box
edit the following information. On the Module Definition dialog box, notice that the automaticallyassigned controller tags DriveStatus, Feedback, LogicCommand, and Reference are always used. However, when using Datalinks you must still assign Host Parameters 01…16 - [DL From Net 01-16] and Host Parameters 17…32 - [DL To Net 01-16] to point to the appropriate drive or connected peripheral Box Setting Revision The major and minor revision of the firmware (database) in the drive. If the drive’s major and minor revision is not available, the drive database is not installed on your computer. To get the correct database revision, use one of the following buttons at the bottom left of the Module Definition dialog box: ? Create Database: Creates a database from an online network drive. Clicking this button displays an RSLinx software RSWho dialog box. Browse to the online drive (for this example, PowerFlex 753), select it, and click OK. The database will be uploaded and stored on the computer. Thereafter, close the Module Definition dialog box and then re-open it to display the new revision. ? Web Update: When a drive is not available online, opens the Allen-Bradley Drives Web Updates website to download a specific database file.
After downloading the file
close the Module Definition dialog box and then re-open it to display the new revision. ? Match Drive: Use this button when the drive being added to the network matches the drive profile (revision, rating, Datalinks, configuration settings, and so forth) of an existing online network drive. Click this button to conveniently create a duplicate drive profile from the online drive, and automatically load this identical information into the Module Definition dialog box. This eliminates the need to manually enter the information each time a new drive with a matching profile is added to the network. Electronic Keying Compatible Module. The “Compatible Module” setting for Electronic Keying verifies that the physical module is consistent with the software configuration before the controller and bridge make a connection. Therefore, be sure that you have set the correct revision in this dialog box. See the online Help for additional information on this and other Electronic Keying settings. If keying is not required, select “Disable Keying.” Drives do not require keying, and so “Disable Keying” is recommended. When using RSLogix 5000 software, version 20 or later, and Automatic Device Configuration (ADC) with Firmware Supervisor upgrade support to store firmware for the drive, always choose “Exact Match.” When using ADC, see the table on page 70 for more details.
公司主營產(chǎn)品圖展示
產(chǎn)品優(yōu)勢(shì)
1:國外專業(yè)的供貨渠道,具有價(jià)格優(yōu)勢(shì)
2:產(chǎn)品質(zhì)量保證,讓您售后無憂
3:全國快遞包郵
4:一對(duì)一服務(wù)
公司主營范圍簡(jiǎn)介
PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動(dòng)監(jiān)測(cè)系統(tǒng)卡件,汽輪機(jī)控制系統(tǒng)模塊,燃?xì)獍l(fā)電機(jī)備件等,優(yōu)勢(shì)品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進(jìn)口工業(yè)零部件、歐美進(jìn)口模塊。
產(chǎn)品廣泛應(yīng)用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機(jī)械、電子制造、汽車制造、塑膠機(jī)械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等