產(chǎn)品內(nèi)容介紹
A-B 80190-060-03-R控制器傳輸速率
設(shè)置選項模塊
節(jié)點地址
當節(jié)點地址開關(guān)(第21頁圖2)設(shè)置為其他值時001…254或888,設(shè)備參數(shù)05-[Net Addr Sel]決定選項模塊節(jié)點地址的源。默認情況下,節(jié)點地址開關(guān)設(shè)置為999,設(shè)備參數(shù)05-[Net Addr Sel]設(shè)置為“3”
(DHCP)。此組合選擇DHCP服務(wù)器作為節(jié)點的源住址要使用BOOTP或DHCP服務(wù)器設(shè)置節(jié)點地址,請參閱下面的小節(jié)。要使用選項模塊參數(shù),請參閱使用選項模塊
第36頁上的參數(shù)。如果PowerFlex 750系列驅(qū)動器連接到Stratix 6000或Stratix 8000
受管以太網(wǎng)交換機和驅(qū)動器設(shè)置為BOOTP模式,“動態(tài)IP
按端口分配地址'(Stratix 6000)或'DHCP持久性'(Stratix 8000)功能將設(shè)置驅(qū)動器的IP地址。有關(guān)更多詳細信息,請參閱Stratix6000以太網(wǎng)管理交換機用戶手冊,出版物1783-UM001,或Stratix 8000和Stratix 8300以太網(wǎng)網(wǎng)管交換機用戶手冊,出版物1783-UM003。
?使用HIM滾動至選項模塊所在的驅(qū)動器端口安裝并訪問選項模塊的DIAGNOSTIC文件夾屏幕。
然后滾動至診斷項目49…54(硬件地址1…6)以查看選項模塊的硬件以太網(wǎng)地址(MAC)。
使用選項模塊參數(shù)默認情況下
選項模塊配置為使用DHCP服務(wù)器作為源用于選項模塊的IP地址、子網(wǎng)掩碼和網(wǎng)關(guān)地址。到請改用選項模塊參數(shù),您必須首先更改節(jié)點地址設(shè)置為“參數(shù)”,然后設(shè)置相關(guān)選項模塊參數(shù)。要將此配置永久分配給選項模塊,請選擇設(shè)備,然后單擊禁用BOOTP/DHCP。
當選項模塊上的電源循環(huán)時,它將使用配置您分配了它,但沒有發(fā)出新的BOOTP/DHCP請求。
從文件菜單中,選擇保存以保存關(guān)系列表。
盒子類型IP地址(1) 有關(guān)此術(shù)語的定義,請參閱術(shù)語表。
選項模塊的唯一IP地址主機名可選
說明可選提示:為具有BOOTP的選項模塊啟用BOOTP或DHCP/DHCP已禁用,請首先在關(guān)系列表中選擇選項模塊。
然后,根據(jù)服務(wù)器類型,單擊啟用BOOTP或啟用DHCP,最后,重置選項模塊或重啟驅(qū)動器。默認情況下,選項模塊設(shè)置為自動檢測,因此它會自動檢測網(wǎng)絡(luò)上使用的數(shù)據(jù)速率和雙工設(shè)置。
如果需要設(shè)置特定數(shù)據(jù)速率和雙工設(shè)置,設(shè)備參數(shù)19-[Net rate Cfg 1]的值確定用于以下目的的以太網(wǎng)數(shù)據(jù)速率和雙工設(shè)置在選項模塊的ENET1網(wǎng)絡(luò)端口上通信。有關(guān)數(shù)據(jù)速率和雙工,請參閱詞匯表。
Setting the Option Module Node Address
When the Node Address switches (Figure 2 on page 21) are set to a value other than 001…254 or 888, Device Parameter 05 - [Net Addr Sel] determines the source for the option module node address. By default, the Node Address switches are set to 999 and Device Parameter 05 - [Net Addr Sel] is set to “3” (DHCP). This combination selects a DHCP server as the source for the node address. To use a BOOTP or DHCP server to set the node address, see the subsection below. To use option module parameters, see Using Option Module Parameters on page 36.If the PowerFlex 750-Series drive is connected to a Stratix 6000 or Stratix 8000 managed Ethernet switch and the drive is set for BOOTP mode, the ‘dynamic IP address assignment by port’ (Stratix 6000) or ‘DHCP persistence’ (Stratix 8000) feature will set the IP address for the drive. For more details, see the Stratix 6000 Ethernet Managed Switch User Manual, publication 1783-UM001, or the Stratix 8000 and Stratix 8300 Ethernet Managed Switches User Manual, publication 1783-UM003.? Use the HIM to scroll to the drive Port in which the option module is installed and access the option module’s DIAGNOSTIC folder screen. Then scroll to Diagnostic Items 49…54 (HW Addr 1…6) to view the option module’s hardware Ethernet Address (MAC).
Using Option Module Parameters
By default, the option module is configured to use a DHCP server as the source for the IP address, subnet mask, and gateway address for the option module. To use option module parameters instead, you must first change the source for the node address to “Parameters” and then set the associated option module parameters as described in the following subsections.To permanently assign this configuration to the option module, select the device in the Relation List and click Disable BOOTP/DHCP. When power is cycled on the option module, it will use the configuration you assigned it and not issue new BOOTP/DHCP requests. 11. From the File menu, choose Save to save the Relation List. Box Type IP Address (1) (1) For definition of this term, see the Glossary. A unique IP address for the option module Host Name Optional Description Optional TIP To enable BOOTP or DHCP for an option module that has had BOOTP/ DHCP disabled, first select the option module in the Relation List. Then, depending on the type of server, click Enable BOOTP or Enable DHCP and, lastly, reset the option module or power cycle the drive.By default, the option module is set to autodetect, so it automatically detects the data rate and duplex setting used on the network. If you need to set a specific data rate and duplex setting, the value of Device Parameter 19 - [Net Rate Cfg 1] determines the Ethernet data rate and duplex setting that will be used to communicate on the option module’s ENET1 network port. For definitions of data rate and duplex, see the Glossary.
公司主營產(chǎn)品圖展示
產(chǎn)品優(yōu)勢
1:國外專業(yè)的供貨渠道,具有價格優(yōu)勢
2:產(chǎn)品質(zhì)量保證,讓您售后無憂
3:全國快遞包郵
4:一對一服務(wù)
公司主營范圍簡介
PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動監(jiān)測系統(tǒng)卡件,汽輪機控制系統(tǒng)模塊,燃氣發(fā)電機備件等,優(yōu)勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進口工業(yè)零部件、歐美進口模塊。
產(chǎn)品廣泛應(yīng)用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車制造、塑膠機械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等