公司主營(yíng)產(chǎn)品圖展示產(chǎn)品優(yōu)勢(shì)1:國(guó)外專業(yè)的供貨渠道,具有價(jià)格優(yōu)勢(shì)2:產(chǎn)品質(zhì)量保證,讓您售后無(wú)憂3:全國(guó)快遞包郵4:一對(duì)一服務(wù)產(chǎn)品詳情介紹IBA ibaFOB-4i-S工業(yè)數(shù)據(jù)采集卡二進(jìn)制模塊的設(shè)置和診斷下表概述了I/O配置和相關(guān)診斷功能用于不同的模塊類型。說(shuō)明功能完全可用。設(shè)置和錯(cuò)誤可以從相關(guān)頻道進(jìn)行詢問。部分功能可用,請(qǐng)參閱模塊說(shuō)明。1) 關(guān)于設(shè)置和診斷數(shù)據(jù),請(qǐng)參見模塊說(shuō)明和章節(jié)“讀取I/O配置和...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

IBA ibaFOB-4i-S工業(yè)數(shù)據(jù)采集卡

    公司主營(yíng)產(chǎn)品圖展示

    微信圖片_20220919175923.jpg

    產(chǎn)品優(yōu)勢(shì)

    1:國(guó)外專業(yè)的供貨渠道,具有價(jià)格優(yōu)勢(shì)

    2:產(chǎn)品質(zhì)量保證,讓您售后無(wú)憂

    3:全國(guó)快遞包郵

    4:一對(duì)一服務(wù)

    產(chǎn)品詳情介紹

    IBA ibaFOB-4i-S工業(yè)數(shù)據(jù)采集卡

    二進(jìn)制模塊的設(shè)置和診斷

    下表概述了I/O配置和相關(guān)診斷功能用于不同的模塊類型。說(shuō)明功能完全可用。設(shè)置和錯(cuò)誤可以從相關(guān)頻道進(jìn)行詢問。

    部分功能可用,請(qǐng)參閱模塊說(shuō)明。

    1) 關(guān)于設(shè)置和診斷數(shù)據(jù),請(qǐng)參見模塊說(shuō)明和章節(jié)“讀取I/O配置和診斷模塊中的數(shù)據(jù)”(見下文)。BE總線錯(cuò)誤=總線故障,始終受到監(jiān)控。這個(gè)模塊未收到總線主控器的呼叫,

    e、 因?yàn)楣痪€路斷了。CI輸入斷線=斷路(監(jiān)控)輸入(如果已配置)。每個(gè)輸入電路監(jiān)控裝置必須配備一個(gè)電阻20…30 k,例如與信號(hào)觸點(diǎn)并聯(lián)。CO切斷輸出線=斷路(監(jiān)控)輸出(如果已配置)。每個(gè)輸出都需要

    當(dāng)ON信號(hào)為輸出ID輸入延遲=信號(hào)延遲時(shí)間的變化輸入。

    僅IO輸入=每個(gè)終端(通道)可以配置為僅作為輸入(而不是作為組合輸入/輸出)。

    僅限OO輸出=此模式通過(guò)開關(guān)設(shè)置

    在插入式底座ECZ上。無(wú)法通過(guò)I/O進(jìn)行設(shè)置配置,請(qǐng)參閱模塊說(shuō)明。

    OL過(guò)載(始終受到監(jiān)控)。

    SC短路(始終受到監(jiān)控)。

    UE單元錯(cuò)誤=模塊的內(nèi)部錯(cuò)誤(故障)(始終盡可能監(jiān)控內(nèi)部處理器檢測(cè)到此)。說(shuō)明:1) 關(guān)于設(shè)置和診斷數(shù)據(jù),請(qǐng)參見模塊說(shuō)明和章節(jié)“讀取I/O配置和診斷模塊中的數(shù)據(jù)”(見下文)。*)通過(guò)開關(guān)改變范圍,激活斷路通過(guò)I/O配置進(jìn)行監(jiān)控BE總線錯(cuò)誤=總線故障,始終受到監(jiān)控。這個(gè)模塊未收到總線主控器的呼叫,e、 因?yàn)楣痪€路斷了。OE輸出錯(cuò)誤=輸出電路中的錯(cuò)誤。

    ICSA 04 B5:配置為4…20毫安。

    ICSM 06 A6:配置為+10伏。UE單元錯(cuò)誤=模塊的內(nèi)部錯(cuò)誤(故障)(始終盡可能監(jiān)控內(nèi)部處理器檢測(cè)到這一點(diǎn))。

    A出廠設(shè)置K通過(guò)I/O配置更改范圍通過(guò)CS31系統(tǒng)總線S通過(guò)DIL開關(guān)改變量程模塊后側(cè)V電壓和電流之間的轉(zhuǎn)換額外的外部跳線。無(wú)規(guī)范,如果只需使用另一個(gè)終端。

    Settings and diagnosis on binary modules The following tables give you an overview on the I/O configurations and the diagnosis functions related to them for the different module types.Explanation  Feature is completely available. Settings and errors can be interrogated from the involved channel. () Feature is partly available, see module description. 1) Concerning the interrogation of settings and diagnosis data, see the module description and chapter ”Reading I/O configuration and diagnosis data at the module” (see below). BE Bus Error = Bus malfunction, always monitored. The module does not receive a call from the bus master, e.g. because of a broken bus line. CI Cut Wire of Inputs = Open circuit (monitoring) at inputs, if configured. Each input circuit to be monitored has to be equipped with a resistor of 20...30 k, e.g. in parallel to the signalling contact. CO Cut Wire of Outputs = Open circuit (monitoring) at outputs, if configured. Each output expects a minimum load of approx. 40 mA when an ON signal is output. ID Input Delay = Change of the signal delay time at inputs. IO Input only = Each terminal (channel) can be configured so that it works only as an input (not as combined input/output). OO Output only = This mode is set by means of a switch on the plug-in base ECZ. Setting is not possible by I/O configuration, see the module description. OL Overload (is always monitored). SC Short circuit (is always monitored). UE Unit error = internal error (fault) of the module (always monitored in so far as the internal processor can detect this).

    Explanation: 1) Concerning the interrogation of settings and diagnosis data, see the module description and chapter ”Reading I/O configuration and diagnosis data at the module” (see below). *) Changing range by switch, activating the open-circuit monitoring by I/O configuration BE Bus Error = Bus malfunction, always monitored. The module does not receive a call from the bus master, e.g. because of a broken bus line. OE Output Error = Error in the output circuit. ICSA 04 B5: Open circuit at outputs configured to 4...20 mA. ICSM 06 A6: Short circuit at outputs configured to + 10 V. UE Unit error = internal error (fault) of the module (always monitored in so far as the internal processor can detect this). A Factory setting K Changing the range by means of the I/O configuration via the CS31 system bus S Changing the range by means of DIL switches on the rear side of the module V Change-over between voltage and current by means of an additional external jumper. No specification if only another terminal has to be used.