国产精品久久二区二区,熟女少妇内射日韩亚洲,久久亚洲国产成人精品无码区,GOGO熟女少妇大尺度

您的瀏覽器版本過低,為保證更佳的瀏覽體驗,請點擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設備有限公司網站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:xiamen2018@foxmail.com

主頁 > 產品中心 > SCHNEIDER

SCHNEIDER

ABB >>

A-B>>

GE>>

BENTLY>>

140XBP00400

140XBP00400

主營產品PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動監測系統卡件,汽輪機控制系統模塊,燃氣發電機備件等,優勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、P...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

140XBP00400

    主營產品

    PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動監測系統卡件,汽輪機控制系統模塊,燃氣發電機備件等,優勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進口工業零部件

    產品廣泛應用于冶金、石油天然氣、玻璃制造業、鋁業、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車制造、塑膠機械、電力、水利、水處理/環保、鍋爐供暖、能源、輸配電等等

    140XBP00400脈沖輸入模塊

    三角模式觸發瞬間的定義以及二進制信號如何被記錄。配置的模擬信道始終為:記錄。可能的設置: TrigByStart:當保護功能拾取(一般拾取)。二進制的不記錄信號。

     TrigByTrip:當保護功能跳閘(一般跳閘)。二進制信號是沒有記錄。

     TrigByBin1:干擾記錄器由二進制I/P 1。不記錄二進制信號。

     TrigAnyBin:記錄定義的二進制信號,并通過或門觸發記錄。

     TrStrt和Bin:記錄定義的二進制信號,并通過或門和

    當保護功能啟動時(一般啟動)。

     TrTrip和Bin:記錄定義的二進制信號,并通過或門和

    當保護功能跳閘時(一般拾取)。三相電流合理性(檢查-I3ph)A、 應用檢查三相電流輸入的合理性:

    監測三相系統的對稱性

    剩余電流檢測監督c.t.輸入通道。B、 特征評估

    三相電流之和

    三相電流的順序

    用于比較三相電流之和的規定

    具有剩余電流I/P剩余電流幅度的調整

    大電流下的阻塞(大于2 x IN)

    小電流下相序監測的阻塞(小于0.05 x英寸)

    對直流組件不敏感

    對諧波不敏感三相電壓合理性(檢查-U3ph)

    檢查三相電壓輸入的合理性:剩余電壓檢測監測三相電壓系統的不對稱性

    由于零序分量監控v.t.輸入通道。

    B、 特征評價三相電壓之和

    三相電壓的順序

    用于比較三相電壓之和的規定具有剩余電壓I/P

    剩余電壓幅度的調整高壓下的閉鎖(高于1.2 x UN)

    小電壓下相序監測的阻斷(低于0.4 x UN相間電壓)

    對直流組件不敏感

    對諧波不敏感。

    只有在Y的情況下才可能評估相電壓

    連接的I/P變壓器,否則剩余組件無法檢測到。

    TrigMode

    Definition of the instant of triggering and how binary signals

    are recorded. The configured analogue channels are always

    recorded. Possible settings:

     TrigByStart: The disturbance recorder is triggered when a

    protection function picks up (general pick-up). Binary

    signals are not recorded.

     TrigByTrip: The disturbance recorder is triggered when a

    protection function trips (general trip). Binary signals are

    not recorded.

     TrigByBin1: The disturbance recorder is triggered by the

    binary I/P 1. Binary signals are not recorded.

     TrigAnyBin: Defined binary signals are recorded and recording is triggered by any of them via an OR gate.

     TrStrt&Bin: Defined binary signals are recorded and recording is triggered by any of them via an OR gate and

    also when a protection function picks up (general pickup).

     TrTrip&Bin: Defined binary signals are recorded and recording is triggered by any of them via an OR gate and

    also when a protection function trips (general pick-up). Three-phase current plausibility (Check-I3ph)

    A. Application

    Checking the plausibility of the three-phase current inputs for

     monitoring the symmetry of the three-phase system

     detection of a residual current

     supervision of the c.t. input channels.

    B. Features

     evaluation of

     the sum of the three phase currents

     the sequence of the three phase currents

     provision for comparing the sum of the three phase currents

    with a residual current I/P

     adjustment of residual current amplitude

     blocking at high currents (higher than 2 x IN)

     blocking of phase sequence monitoring at small currents

    (below 0.05 x IN)

     insensitive to DC components

     insensitive to harmonics Three-phase voltage plausibility (Check-U3ph)

    A. Application

    Checking the plausibility of the three-phase voltage inputs for

     detection of residual voltage

     monitoring the asymmetry of the three-phase voltage system

    due to the zero-sequence component

     supervision of the v.t. input channels.

    B. Features

    evaluation of

     the sum of the three phase voltages

     the sequence of the three phase voltages

     provision for comparing the sum of the three phase voltages

    with a residual voltage I/P

     adjustment of residual voltage amplitude

     blocking at high voltages (higher than 1.2 x UN)

     blocking of phase sequence monitoring at small voltages

    (below 0.4 x UN phase-to-phase voltages)

     insensitive to DC components

     insensitive to harmonics.

    Evaluation of the phase voltages is only possible in the case of Y

    connected I/P transformers, otherwise the residual component

    cannot be detected.

    品牌:140PLC系列

    型號:140XBP00400

    產地:美國

    質保:365天

    成色:全新/二手

    發貨方式:快遞發貨


圖片名 客服

在線客服 客服一號