BENTLY 136188-01

BENTLY 136188-01

主營產品PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動監測系統卡件,汽輪機控制系統模塊,燃氣發電機備件等,優勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、P...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

BENTLY 136188-01

    主營產品

    PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動監測系統卡件,汽輪機控制系統模塊,燃氣發電機備件等,優勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進口工業零部件

    產品廣泛應用于冶金、石油天然氣、玻璃制造業、鋁業、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車制造、塑膠機械、電力、水利、水處理/環保、鍋爐供暖、能源、輸配電等等

    BENTLY 136188-01監測繼電器

    定義運行函數的處理單元。ParSet 4..1用于確定特定功能在哪一組參數中激活的參數(見第5.11節)。

    電流輸入模擬電流I/P通道。所有當前I/P可供選擇。角測量實際功率的特征角。在測量視在時也考慮相位角權力不應改變0.0度的默認設置,測量時電壓和電流I/P同相時純實功率,例如測量接地相位時同一導體的電壓和電流。在以下情況下,設置可能從0.0變化:c.t.和v.t.相位誤差補償

    相接地和相對相電壓之間的相移補償電壓和電流之間的相移補償一般電流(例如,測量S-T電壓和R電流)。電壓InP定義v.t.輸入通道。所有電壓I/P可供選擇。

    PN被測功率的參考值。

    這使得被測功率的振幅能夠:例如考慮額定功率因數。

    電壓模式

    電壓測量方法的定義以及功率的計算。設置:相接地:所選電壓I/P的電壓為直接測量。

    相-相-相電壓由測量所選電壓I/P和周期滯后電壓通道。

    當只有單相連接或相-相電壓被連接。設置說明必須仔細設置測量功能,以獲得

    這是最好的準確性。必須遵守以下規定:C.t./v.t.輸入通道參考值

    電壓和電流模擬的參考值輸入通道必須設置為,當額定值

    應用于I/P,測量1.000 UN和1.000 IN通過函數。

    在大多數情況下,可以保留c.t.和v.t.輸入通道的默認參考設置(1.000)。筆記對三相電壓或電流I/P的參考值所做的任何改變適用于所有相。

    Explanation of parameters

    RunOnCPU

    defines the processing unit which runs the function.

    ParSet 4..1

    Parameter for determining in which set of parameters a particular function is active (see Section 5.11.).

    CurrentInp

    Analogue current I/P channel.

    All current I/P's are available for selection.

    Angle

    Characteristic angle for measuring real power. The phaseangle is also taken into account when measuring apparent

    power.

    The default setting of 0.0 degrees should not be changed,

    when voltage and current I/P's are in phase when measuring

    purely real power, e.g. when measuring the phase-to-ground

    voltage and current of the same conductor.

    The setting may vary from 0.0 in the following cases:

     compensation of c.t. and v.t. phase errors

     compensation of the phase-shift between phase-toground and phase-to-phase voltages

     compensation of the phase-shift between voltage and

    current in general (e.g. when measuring S-T voltage and

    R current).VoltageInp

    Defines the v.t. input channel.

    All voltage I/P's are available for selection.

    PN

    Reference value for the power being measured.

    This enables the amplitude of the power being measured to

    be adjusted, e.g. to take account of the rated power factor.

    Voltage mode

    Definition of the method of voltage measurement and therefore also the calculation of power. Settings:

     phase-to-ground The voltage of the selected voltage I/P is

    measured directly.

     phase-to-phase The phase-to-phase voltage formed by

    the selected voltage I/P and the cyclically lagging voltage channel is measured.

    This setting is not permitted when only a

    single-phase is connected or when

    phase-to-phase voltages are connected.Setting instructions

    The measurement function must be carefully set to obtain the

    best accuracy. The following must be observed:

     C.t./v.t. input channel reference values

    The reference values for the voltage and current analogue

    input channels must be set such that, when the rated values

    are applied to the I/P's, 1.000 UN and 1.000 IN are measured

    by the function.

    In most cases, it will be possible to retain the default reference setting (1.000) for the c.t. and v.t. input channels. Note

    that any changes made to the reference value of a threephase voltage or current I/P apply to all phases.