WES5302-150

主營產品PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動監測系統卡件,汽輪機控制系統模塊,燃氣發電機備件等,優勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、P...

  • 功能特性
  • 參數規格
  • 視頻
  • 應用案例
  • 下載

WES5302-150

    主營產品

    PLC可編程控制器模塊,DCS卡件,ESD系統卡件,振動監測系統卡件,汽輪機控制系統模塊,燃氣發電機備件等,優勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進口工業零部件

    產品廣泛應用于冶金、石油天然氣、玻璃制造業、鋁業、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車制造、塑膠機械、電力、水利、水處理/環保、鍋爐供暖、能源、輸配電等等

    WES5302-150自動化卡件

    當發出關閉命令時,該信號開始出現,并且如果在重合閘時發生跳閘,則在時間“t Close”結束或更早時復位。自動重合閘功能的狀態(“AR就緒”和“AR阻塞的‘)

    自動重合閘時產生信號“AR就緒”功能已準備好執行重合閘循環,信號“AR當它被阻止時“被阻止”。

    “AR就緒”信號激活,前提是重合閘周期未阻塞(無“AR阻塞”信號)且死區時間未運行。

    “AR就緒”信號在重新閉合命令期間激活啟用同步檢查功能的目的(參見中的圖3同步檢查功能部分)。正在進行自動重合閘循環

    有六個信號表明重合閘循環正在運行,并且達到了什么階段:“程序中的AR”正在進行重合閘循環

    “首次AR 1P”首次單相重合閘嘗試

    “首次AR 3P”首次三相重合閘嘗試“第二次AR”第二次重合閘嘗試

    “第三次AR”和第三次重合閘嘗試

    “第四次AR”是第四次重合閘嘗試。

    信號“AR in prog”在死區時間開始時拾取由最后一個重合閘命令的下降沿復位。

    斷路器閉合信號“閉合CB”和“閉合CB2”

    CB閉合命令通常分配給重型

    通過相應配置參數,輔助O/P繼電器

    “關閉CB”(在雙工方案中也稱為“關閉CB2”)。也可以將相同的信號分配給以下信令O/P:參數名稱相同。

    在“關閉”期間,關閉命令之后的跳閘+300ms切換死區時間步長(第二、第三和第四AR)或啟動鎖定跳閘(取決于設置)。接近跳閘后立即重置命令。

    確定的行程。旅行“Def。“跳閘”信號表示斷路器將保持

    跳閘,不再嘗試再次重合閘。以下情況可能導致最終跳閘:所有重合閘嘗試均未成功

    This signal picks up when the closing command is issued and

    resets at the end of the time ‘t Close’ or earlier if there is a tripping occurs upon reclosing.

    Status of the auto-reclosure function (‘AR Ready’ and ‘AR

    Blocked’)

    The signal ‘AR Ready’ is generated when the auto-reclosure

    function is ready to perform a reclosure cycle and the signal ‘AR

    Blocked’ when it is blocked.

    The ‘AR Ready’ signal is active providing a reclosure cycle is not

    blocked (no ‘AR Blocked’ signal) and a dead time is not running.

    The ‘AR Ready’ signal is active during a reclose command for

    purposes of enabling the synchrocheck function (see Fig. 3 in

    the synchrocheck function section).Auto-reclosure cycle in progress

    There are six signals which show that a reclosure cycle is running and what stage has been reached:

    'AR in prog.' reclosure cycle in progress

    'First AR 1P' first single-phase reclosure attempt

    'First AR 3P' first three-phase reclosure attempt

    ‘second AR' second reclosure attempt

    'Third AR' third reclosure attempt

    'Fourth AR' fourth reclosure attempt.

    The signal ‘AR in prog’ picks up at the start of the dead time and

    is reset by the falling edge of the last reclose command.

    Circuit-breaker closing signals ‘Close CB’ and ‘Close CB2'

    The CB closing command is normally assigned to a heavy-duty

    auxiliary O/P relay by correspondingly configuring the parameter

    ‘Close CB’ (also ‘Close CB2’ in a duplex scheme). It is also possible to assign the same signal to a signalling O/P under the

    same parameter name.

    A trip subsequent to a close command during the time ‘t Close’ +

    300 ms switches the dead time step (second, third and fourth

    AR) or initiates a lock-out trip (depending on the setting). A close

    command is reset immediately after a trip.

    Definitive trip ‘Def. Trip'

    The ‘Def. Trip’ signal indicates that the circuit-breaker will remain

    tripped and no further reclosure attempts will be made. The following conditions can cause a definitive trip:

     All reclosure attempts were unsuccessful