To upgrade the 16-Way AC to DC Power Supply Unit to 150W or
200W proceed as follows:
(1) Fit a second 50W Sub unit, containing a 50W Switched Mode
Module, to the 16-way AC to DC Power Supply Unit front panel
using the fixings supplied.
(2) When an upgrade to 200W is required, fit a further 50W Switched
Mode Module into the new 50W Sub unit as indicated in Section 17.2.
WARNING
High ac mains voltages may be present at the system power supply
unit and at the relay terminals of the interface cards. Appropriate
safety precautions must be taken when commissioning or servicing
the system.
IMPORTANT
Commissioning and maintenance of the system should be carried out
by trained authorised personnel only.
1. GENERAL
The following guide to commissioning and maintenance should be
used in conjunction with the relevant instructions issued with the
sensors being used.
The following information applies to the setup of a system with a single
power supply connection to the DC Input Card. For information on
systems where power is applied to each individual channel, please
contact Zellweger Analytics.
(6) Switch off the power supply.
(7) Reconnect the terminal block TB1 to the DC Input Card.
(8) Switch on the system power supply.
(9) Check that a voltage of between 18V and 32V dc still exists at the
terminal block TB1.
(10) Check that the Engineering Card front panel power on ( ) green
LED is illuminated and the unlocked ( ) LED is flashing.
(11) Push the control card in slot 1 fully into the rack so that it makes
connection with the backplane and secure with the two securing
screws.
(12) Check that the display operates and that the INHIBIT LED on the
control card front panel is illuminated.
(13) Check that after the pre-defined start up inhibit period, typically 30
seconds, the INHIBIT LED is extinguished.