HONEYWELL TK-IOLI01

HONEYWELL TK-IOLI01

HONEYWELL TK-IOLI01模塊,TK-IOLI01中文PDF用戶手冊(cè)擴(kuò)展端口引腳分配下表列出了在以下情況下需要的擴(kuò)展端口引腳分配:建筑遠(yuǎn)程電纜。電纜之間的所有連接都是點(diǎn)對(duì)點(diǎn)的,即針腳2一端連接到另一端的針腳2,針腳3連接到針腳3等。I/O擴(kuò)展總線終端當(dāng)兩個(gè)或多個(gè)基板在擴(kuò)展系統(tǒng)中連接在一起時(shí),輸入/輸出擴(kuò)展總線必須正確端接。輸入/輸出總線必須在最后一個(gè)擴(kuò)展系統(tǒng)中的基板。每個(gè)信號(hào)對(duì)端接12...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

HONEYWELL TK-IOLI01

    HONEYWELL TK-IOLI01模塊,TK-IOLI01中文PDF用戶手冊(cè)

    擴(kuò)展端口引腳分配下表列出了在以下情況下需要的擴(kuò)展端口引腳分配:建筑遠(yuǎn)程電纜。電纜之間的所有連接都是點(diǎn)對(duì)點(diǎn)的,即針腳2一端連接到另一端的針腳2,針腳3連接到針腳3等。I/O擴(kuò)展總線終端當(dāng)兩個(gè)或多個(gè)基板在擴(kuò)展系統(tǒng)中連接在一起時(shí),輸入/輸出擴(kuò)展總線必須正確端接。輸入/輸出總線必須在最后一個(gè)擴(kuò)展系統(tǒng)中的基板。每個(gè)信號(hào)對(duì)端接120歐姆,1/4瓦在適當(dāng)引腳之間接線的電阻器如下(另見上表)

    TK-IOLI01 51403427-175.jpg

    HONEYWELL TK-IOLI01模塊:針腳16-17;24 - 25; 20 - 21; 12 - 13; 8 - 9; 2 - 3輸入/輸出總線終端可以通過以下方式之一完成:通過在最后一個(gè)端口上安裝目錄號(hào)為IC693ACC307的輸入/輸出總線終端插頭系統(tǒng)中的擴(kuò)展基板(本地?cái)U(kuò)展基板或遠(yuǎn)程基板)。終端插頭有一個(gè)物理安裝在連接器內(nèi)部的電阻器組。輸入/輸出總線終端插頭隨每個(gè)基板一起裝運(yùn);只有最后一個(gè)基板在擴(kuò)展鏈中,可以安裝輸入/輸出總線終端插頭。未使用的輸入/輸出總線終端插頭可以丟棄或作為備件保存。如果擴(kuò)展系統(tǒng)只有一個(gè)擴(kuò)展基板,則輸入/輸出總線可以通過將50英尺(15米)輸入/輸出擴(kuò)展電纜作為最后一根電纜安裝而終止,目錄號(hào)IC693CBL302或IC693CBL314。這些電纜具有終端電阻器安裝在與擴(kuò)展基板連接器連接的一端。您還可以構(gòu)建一條自定義電纜,將終端電阻連接到適當(dāng)?shù)挠糜诎惭b在總線末端的銷。

    Expansion Port Pin Assignments

    The following table lists the expansion port pin assignments you will need when

    building remote cables. All connections between cables are point-to point, that is, pin 2

    of one end to pin 2 of the opposite end, pin 3 to pin 3, etc.I/O Expansion Bus Termination

    When two or more baseplates are cabled together in an expansion system, the I/O

    expansion bus must be properly terminated. The I/O bus must be terminated at the last

    baseplate in an expansion system. Each signal pair is terminated with 120 ohm, 1/4 watt

    resistors wired between the appropriate pins, as follows (see the above table, also):

    pins 16 - 17; 24 - 25; 20 - 21; 12 - 13; 8 - 9; 2 - 3

    The I/O bus termination can be done one of the following ways:

     By installing an I/O Bus Terminator Plug, catalog number IC693ACC307, on the last

    expansion baseplate (local expansion baseplate or remote baseplate) in the system.

    The Terminator Plug has a resistor pack physically mounted inside of a connector.

    The I/O Bus Terminator Plug is shipped with each baseplate; only the last baseplate

    in the expansion chain can have the I/O Bus Terminator Plug installed. Unused I/O

    Bus Terminator Plugs can be discarded or saved as spares.

     If an expansion system has only one expansion baseplate, the I/O bus can be

    terminated by installing as the last cable, the 50 foot (15 meter) I/O Expansion cable,

    catalog number IC693CBL302 or IC693CBL314. These cables have the termination

    resistors installed in the end that connects to the expansion baseplate connector.

     You can also build a custom cable with termination resistors wired to the appropriate

    pins for installation at the end of the bus.