EPRO MMS6120前置傳感器,MMS6120使用配置說明
大多數(shù)Genius NIU故障將出現(xiàn)在輸入/輸出的輸入/輸出故障表中控制器。但是,一些Genius NIU故障(例如機架丟失和系統(tǒng)配置不匹配)出現(xiàn)在控制器的PLC中故障表。天才牛兒報告未解決的故障清除控制器的輸入/輸出故障表。它不會重新報告清除PLC故障表時未解決的PLC故障。清除故障時,清除其中的PLC和輸入/輸出故障表順序然后查看輸入/輸出和PLC故障表,以確定Genius NIU站的狀態(tài)。
EPRO MMS6120前置傳感器安裝在Genius NIU和任何增壓器上的電源應為同一機架中使用的電源供電斷斷續(xù)續(xù)地在一起。4.Genius NIU對寫入配置沒有響應數(shù)據(jù)報COMMREQ。應用程序必須發(fā)讀取配置數(shù)據(jù)報以確定先前寫入配置數(shù)據(jù)報。
5.如果Genius NIU是使用數(shù)據(jù)報配置的(例如,通過向Genius總線控制器發(fā)出COMMREQ),則強制BSM位可訪問,但不得更改。
6、如果Genius NIU的CPU冗余參數(shù)設置為“Duplex”,輸入/輸出中不得使用模擬輸出和智能模塊
智能輸入/輸出模塊(IC200ALG240、ALG331、ALG620、ALG630、,MDD841)不應長距離使用擴展系統(tǒng)。如果機架中有智能輸入/輸出模塊遠距離擴展系統(tǒng)是電力循環(huán)的,或者如果單個插槽Genius配置數(shù)據(jù)報被發(fā)送到智能模塊在遠距離擴展機架中,其他擴展機架Genius網(wǎng)絡上的其他設備可能會默認簡要輸出。
Most Genius NIU faults will appear in the I/O fault table of the I/O
controller. However, some Genius NIU faults (such as Loss of rack
and System configuration mismatch) appear in the controller’s PLC
fault table. The Genius NIU re-reports unresolved faults when the
controller’s I/O fault table is cleared. It does not re-report
unresolved PLC faults when the PLC fault table is cleared.
When clearing faults, clear both the PLC and I/O fault tables in that
order. Then view both the I/O and PLC fault tables to ascertain the
Genius NIU station’s status.
3. The power supply mounted on a Genius NIU and any booster
power supplies that are used in the same rack should be powered
on and off together.
4. There is no response from the Genius NIU to a Write Configuration
Datagram COMMREQ. The application program must issue a
Read Configuration Datagram to determine the effectiveness of a
previous Write Configuration Datagram.
5. If the Genius NIU is configured using datagrams (for example, by
issuing a COMMREQ to a Genius Bus Controller), the value of the
Force BSM bit is accessible but must not be changed.
6. If the Genius NIU's CPU Redundancy parameter is set to "Duplex",
analog output and intelligent modules must not be used in the I/O
Station.
7. Intelligent I/O modules (IC200ALG240, ALG331, ALG620, ALG630,
and MDD841) should not be used in an extended distance
expansion system. If a rack with an intelligent I/O module in an
extended distance expansion system is power cycled, or if a single
slot Genius configuration datagram is sent to an intelligent module
in an extended distance expansion rack, the other expansion racks
and the other devices on the Genius network may default their
outputs briefly.