E33NRHA-LNN-NS-00

E33NRHA-LNN-NS-00

KOLLMORGEN E33NRHA-LNN-NS-00電機(jī),E33NRHA-LNN-NS-00使用方法輸入具有二階低通硬件濾波器和數(shù)字濾波器單個(gè)時(shí)間常數(shù)為0.5至32 ms。除了車(chē)載輸入/輸出,直接輸入/輸出系統(tǒng)支持S200輸入/輸出。最多八個(gè)外部輸入/輸出單元可以直接插入安裝在控制器上DIN導(dǎo)軌和其他八個(gè)輸入/輸出單元可以通過(guò)TK210電纜連接(長(zhǎng)度0.5、1.0、,或2.5 m)和200-A...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

E33NRHA-LNN-NS-00

    KOLLMORGEN E33NRHA-LNN-NS-00電機(jī),E33NRHA-LNN-NS-00使用方法

    輸入具有二階低通硬件濾波器和數(shù)字濾波器單個(gè)時(shí)間常數(shù)為0.5至32 ms。

    除了車(chē)載輸入/輸出,直接輸入/輸出系統(tǒng)支持S200輸入/輸出。最多八個(gè)外部輸入/輸出單元可以直接插入安裝在控制器上DIN導(dǎo)軌和其他八個(gè)輸入/輸出單元可以通過(guò)TK210電纜連接(長(zhǎng)度0.5、1.0、,或2.5 m)和200-AIO適配器。一排輸入/輸出單元可以使用200-CE1或200-CE3電纜,0.3和0.9米分別(不能與2.5米TK210電纜)。請(qǐng)注意,TK210電纜根據(jù)UL1604,危險(xiǎn)位置不允許超過(guò)0.9 m。

    E33NRHA-LNN-NS-00 二手 (1).jpg

    遠(yuǎn)程輸入/輸出–PROFIBUS-DPCI274板是PROFIBUS-DP現(xiàn)場(chǎng)總線(xiàn),用于遠(yuǎn)程連接S800輸入/輸出、S800L輸入/輸出、,S200輸入/輸出、S20KOLLMORGEN E33NRHA-LNN-NS-00電機(jī)0L輸入/輸出和第三方裝置最大長(zhǎng)度為100至1200 m,取決于波特率。

    S800輸入/輸出單元連接到一個(gè)或多個(gè)輸入/輸出適配器,CI830。其他單位可以是通過(guò)光纖連接到CI830適配器電纜和光纖接口單元,TB820。

    S200輸入/輸出單元連接到一個(gè)或多個(gè)輸入/輸出適配器,200-APB12,最大每個(gè)適配器有八個(gè)輸入/輸出單元。CI274板充當(dāng)總線(xiàn)主控和處理從/到的循環(huán)讀取和寫(xiě)入奴隸。周期時(shí)間取決于波特率速率和連接的從屬服務(wù)器數(shù)。

    最多可以使用兩個(gè)這樣的板安裝在AC 800C中。車(chē)載通信信道AC 800C有兩個(gè)車(chē)載RJ-45插孔,用于RS-232通道,一個(gè)帶全調(diào)制解調(diào)器

    The inputs have a second-order, low-pass hardware filter and a digital filter with individual time constants 0.5 to 32 ms. In addition to the on-board I/O, the direct I/O system supports S200 I/O. Up to eight external I/O units can be directly plugged onto the controller and installed on the same DIN rail, and another eight I/O units can be connected via a TK210 cable (length 0.5, 1.0, or 2.5 m) and a 200-AIO adapter. A row of I/O units can be split in two by using a 200- CE1 or a 200-CE3 cable, 0.3 and 0.9 m respectively (cannot be combined with the 2.5 m TK210 cable). Note that a TK210 cable longer than 0.9 m is not allowed in hazardous locations according to UL1604. Remote I/O – PROFIBUS-DP The CI274 board is an optional interface for the PROFIBUS-DP field bus and used for remote connection of S800 I/O, S800L I/O, S200 I/O, S200L I/O and third-party units over a maximum length of 100 to 1200 m, depending on baud rate. S800 I/O units are connected to one or more I/O adapters, CI830. Additional units can be connected to the CI830 adapter via optical cables and optical interface units, TB820. S200 I/O units are connected to one or more I/O adapters, 200-APB12, with a maximum of eight I/O units per adapter. The CI274 board serves as bus master and handles cyclic reads and writes from/to the slaves. The cycle time depends on the baud rate and the number of slaves attached. A maximum of two such boards can be installed in AC 800C. On-board communication channels AC 800C has two on-board RJ-45 jacks for RS-232 channels, one with full modem