SR469-P5-HI-A20-E-H繼電保護(hù)器,GE電氣
兩個(gè)?通道軸振動(dòng)監(jiān)測(cè)器A6110是A6000機(jī)器監(jiān)測(cè)的一個(gè)模塊
系統(tǒng)微型?處理器控制的監(jiān)視器與兩個(gè)渦流傳感器一起使用
測(cè)量鏈,用于測(cè)量和監(jiān)測(cè)所有類(lèi)型渦輪機(jī)上的相對(duì)軸振動(dòng),壓縮機(jī)、風(fēng)扇、齒輪裝置等。
監(jiān)視器的兩個(gè)通道可以用作單獨(dú)的通道,也可以鏈接在一起通過(guò)配置。可以采用以下操作模式:
SR469-P5-HI-A20-E-H繼電保護(hù)器?雙通道操作。
?根據(jù)ISO 10817(DIN)計(jì)算和輸出最大值Smax45670,特征值A(chǔ))。
?根據(jù)ISO計(jì)算和輸出更大的振動(dòng)寬度SPPmax10817(DIN 45 670,特征值B)或符合API 670的最大值(X,Y)。特征值可以通過(guò)0/4。。。每個(gè)通道的20mA電流輸出交付范圍以下零件包括在交付范圍內(nèi),并且必須包含在裝運(yùn)中:
SR469-P5-HI-A20-E-H繼電保護(hù)器?軸振動(dòng)監(jiān)測(cè)器A6110
?本產(chǎn)品信息附件(不包括在交付范圍內(nèi)):
?彩信輔助套件(訂單號(hào):9510?00027)
如果內(nèi)容不完整或有任何損壞,請(qǐng)直接向持票人投訴。這個(gè)還必須通知epro主管銷(xiāo)售機(jī)構(gòu),以便維修或更換
班長(zhǎng)本儀器的維修或校準(zhǔn)只能在epro進(jìn)行。
The two?channel Shaft Vibration Monitor A6110 is a module of the A6000 machine monitoring
system. The micro?processor controlled monitor is used in conjunction with two eddy current
measuring chains to measure and monitor the relative shaft vibration on all types of turbines,
compressors fans, gear units, etc.
The two channels of the monitor can be used as separate channels or they can be linked together
via the configuration. The following operating modes are possible:
? Dual channel operation.
? The calculation and output of the maximum value Smax in accordance with ISO 10817 (DIN
45670, characteristic value A).
? The calculation and output of the greater vibration width SPPmax in accordance with ISO
10817 (DIN 45 670, characteristic value B) or Max(X,Y) in accordance with API 670.
The characteristic values can be output via a 0/4 ... 20mA current output per channel Scope of Delivery
The following parts are included in the scope of delivery and must be contained in the shipment:
? Shaft Vibration Monitor A6110
? This product information
Accessories (not included in delivery):
? MMS ParaKit (order no.: 9510?00027)
If the contents are incomplete or if is there any damage, so directly complain at the bearer. The
competent epro sales agency must be also informed, to enable repair or replacement for the
monitor. Repair or calibration of this instrument may only be made at